Game ready 550550-03 User Manual

Physical therapy unit
Hide thumbs Also See for 550550-03:

Advertisement

®
G r Pro
2.1 C o N t r o l u N i t
user's Manual
53
Model NuMbers
550550-03, 550550-03-rN, 550550-53
This User's Manual is also available online in
English, French, German, Italian, Japanese, Spanish,
Portuguese, Arabic, Russian, Dutch, Hungarian and Turkish
at www.gameready.com under Support.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 550550-03 and is the answer not in the manual?

Questions and answers

Summary of Contents for Game ready 550550-03

  • Page 1 2.1 C o N t r o l u N i t user’s Manual Model NuMbers 550550-03, 550550-03-rN, 550550-53 This User’s Manual is also available online in English, French, German, Italian, Japanese, Spanish, Portuguese, Arabic, Russian, Dutch, Hungarian and Turkish...
  • Page 2 d e s C r i P t i o N o f t H e G r P r o 2 . 1 s Y s t e M the following items are included in your GrPro 2.1 system: ®...
  • Page 3: Table Of Contents

    A b l e o f C o N t e N t s Introduction to Game Ready _________________________________ 2 Detailed Instructions for Use _________________________________ 3 Modes of Operation _____________________________________ 3 Buttons ________________________________________________ 3 Adjusting Temperature ___________________________________ 4 Display _________________________________________________ 4...
  • Page 4: Introduction To Game Ready

    Warranty Section of this manual. doN’t Just treAt sYMPtoMs, HelP ACCelerAte HeAliNG To learn more or to share your experience with the Game Ready System, please call us at 1.888.426.3732 or email us at info gameready.com. We’d enjoy hearing from you.
  • Page 5: Detailed Instructions For Use

    d e t A i l e d i N s t r u C t i o N s f o r u s e Do not use this device without your physician’s specific recommendations for the frequency and duration of your treatments. The most common recommendation is to use cold therapy at least 4 times a day, for approximately 30 minutes each time, with at least a 30-minute break between treatments.
  • Page 6: Adjusting Temperature

    AdJustiNG teMPerAture To adjust the temperature being applied during treatment, simply turn the temperature knob towards 3 snowflakes for the maximum amount of cold, or towards 1 snowflake for the least amount of cold. Notice that as you adjust the knob, the “Target Temperature” on the display will change.
  • Page 7 Displays the amount of run time Sleep time remaining. count-down bars. When the system Run time count-down bars. is running in Program Mode: Displays the amount of sleep time remaining. When the system Displays the amount of run time is running in remaining.
  • Page 8: Operating The System

    • affect its ability to provide adequate cooling, or may limit the ice life. If you will be using the System with a Game Ready optional battery pack (sold separately), • please consult the instructions for use that accompany that battery pack.
  • Page 9 Add water to fill-line indicated on label within the reservoir. DO NOT OVERFILL. Add ice to top of reservoir. Close the ice box door. Make sure you hear it click. Click Place the Control Unit in the location where you plan to use it. The Control Unit should only be used in the upright orientation as shown.
  • Page 10 Click Disconnect Button If you have any problems with the set-up of your GRPro 2.1 System, in the U.S. call Game Ready Customer Service at 1.888.426.3732 (+1.510.868.2100); from outside of the U.S. please contact your local distributor. Warnings: Follow the treatment recommendations of your health care practitioner •...
  • Page 11 Program d: Drain Mode. Please refer to page 3 in this manual for details. Press play/pause button to start your Game Ready treatment with ACCEL Technology. Press play/pause at any time to stop your treatment. Set to your target temperature (displayed in the Target Temperature window) by turning the knob.
  • Page 12: Storage

    s t o r A G e When you are done using the System for the day: Unplug the AC Adapter and the Connector Hose from the Control Unit. • Push the door release button to open the door. • Carefully pour out the ice and water.
  • Page 13 CoNNeCtor Hose The surface of the Connector Hose can be cleaned using a soft cloth and one of the following: Mild detergent • Steri-Fab • ® 70% Isopropyl alcohol • We do not recommend the use of quaternary ammonium (such as Virex ) or Cavicide.
  • Page 14: Maintenance

    Other than maintaining the reservoir filter, no product service should be performed by the user. If your GRPro 2.1 System requires service, in the U.S. call Game Ready Customer Service at 1.888.426.3732 (+1.510.868.2100); from outside of the U.S. please contact your local distributor.
  • Page 15: Accessories

    A C C e s s o r i e s The GRPro 2.1 Control Unit can be used with any of the following accessories: Any Game Ready Wrap using ATX Series Heat Exchangers (wraps made by any other •...
  • Page 16: General Warnings And Cautions

    For example, the Ankle Wrap is not designed for use on the toes and the Back Wrap is not designed for use in the abdominal region. Compression therapy with the Game ready system should be used only under the supervision of a licensed healthcare practitioner in patients: • Who have an open wound in the affected region (the wound must be dressed prior to...
  • Page 17: Specifications

    To avoid the risk of electrical shock, do not remove any panels from the Control Unit. • Opening the case will void the Game Ready warranty. For all servicing and repair, in the U.S. call Game Ready Customer Service at 1.888.426.3732 (+1.510.868.2100); from outside of the U.S.
  • Page 18: Ul Classification

    Not suitable for use in an oxygen enriched environment or in the presence of flammable anesthetics. Game Ready System as to electrical shock, fire and mechanical hazards only in accordance with EN 60601:2006, CAN/CSA C22.2 No. 60601-1 (2008), and ANSI/AAMI ES60601 (2005 + C1:09 +...
  • Page 19: Electromagnetic Compatibility

    e l e C t r o M A G N e t i C C o M P A t i b i l i t Y electromagnetic Compatibility information According to ieC/eN 60601-1-2 table 1 for emissions GuidANCe ANd MANufACturer’s deClArAtioN – eleCtroMAGNetiC eMissioNs The GRPro 2.1 is intended for use in the electromagnetic environment specified below.
  • Page 20 table 2 for transient electromagnetic immunity GuidANCe ANd MANufACturer’s deClArAtioN – eleCtroMAGNetiC iMMuNitY The GRPro 2.1 is intended for use in the electromagnetic environment specified below. The customer or the user of the GRPro 2.1 should assure that it is used in such an environment. immunitY tEst iEC 60601 tEst lEvEl ComplianCE lEvEl...
  • Page 21 table 3 for rf electromagnetic immunity GuidANCe ANd MANufACturer’s deClArAtioN – eleCtroMAGNetiC iMMuNitY The GRPro 2.1 is intended for use in the electromagnetic environment specified below. The customer or the user of the GRPro 2.1 should assure that it is used in such an environment. immunitY tEst iEC 60601 tEst lEvEl ComplianCE lEvEl...
  • Page 22 table 4 for rf immunity reCoMMeNded sePArAtioN distANCes betWeeN PortAble ANd Mobile rf CoMMuNiCAtioNs equiPMeNt ANd tHe Gr Pro 2.1 The GRPro 2.1 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the GRPro 2.1 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the GRPro 2.1 as recommended below, according to the maximum output power of the communications equipment.
  • Page 23: Troubleshooting

    t r o u b l e s H o o t i N G WHAt does WHAt CAN error it MeAN? i do? • Air Pressure sensor: The This is most likely to occur if you have Control Unit has detected a restarted the System with an inflated Wrap problem calibrating the air attached.
  • Page 24 WHAt does WHAt CAN error it MeAN? i do? • under Pressure: The Make sure the Wrap is applied securely. • Control Unit can’t reach Try using a different Wrap and Hose to its target maximum isolate which component may be producing compression.
  • Page 25 Warnings on page 14 to make sure you take proper steps to minimize the risk of injury. Need more help with a problem? In the U.S. call Game Ready Customer Service at 1.888.426.3732 (+1.510.868.2100); from outside of the U.S. please contact your local distributor.
  • Page 26: Warranty

    How to obtain Warranty service To obtain warranty service, in the U.S. call Game Ready Customer Service at 1.888.426.3732 (+1.510.868.2100); from outside of the U.S. please contact your local distributor. If you are not sure who the local distributor is, call Game Ready Customer Service at +1.510.868.2100 and we will refer you to one.
  • Page 27: Warranty Registration

    Extended Warranties are available for the GRPro 2.1 System. For details and information, in the U.S. call Game Ready Customer Service at 1.888.426.3732 (+1.510.868.2100); from outside of the U.S. please contact your local distributor. A list of current patent(s) covering Game Ready technology can be found at: www.gameready.com/patents. EMERGO EUROPE...
  • Page 28 CoolSystems , Inc. ® 1800 Sutter Street, Suite 500 Concord, CA 94520 USA 1.888.GameReady (1.888.426.3732) +1.510.868.2100 www.gameready.com Game Ready Control Unit User’s Manual PN 703995 Rev B ©2014 CoolSystems, Inc. All rights reserved.