3.6

Grounding the robot system

General instructions on grounding the robot system
Three ways of grounding are shown in Fig. 3-18 .
● Separate grounding is the best solution.
– The robot arm is grounded at an M4 threaded hole (see Fig. 3-19) on the base area.
– The control unit is grounded together with the mains line (feed) connection.
To ground the control unit, proceed as described in Section 4.2.
● If possible, the grounding of the robot arm must be separated from other units/devices.
● The minimum cross-section of the grounding cable must be 3.5 mm² .
● The grounding cable is not included in the scope of delivery of the robot system.
● The grounding cable should be kept as short as possible.
Robot arm
Fig. 3-18: Grounding the robot system
SD-/SQ series
Control unit
and personal
computer
separate grounding
(best solution)
Control unit
Robot arm
and personal
computer
parallel grounding
(good solution)
Grounding the robot system
Control unit
Robot arm
and personal
computer
common grounding
(permissible)
R000451E