Actual Status Display - Siemens Sinamics V90 Operating Instructions Manual

Pulse train, uss/modbus interface
Hide thumbs Also See for Sinamics V90:
Table of Contents

Advertisement

Basic operator panel (BOP)

6.3 Actual status display

6.3
Actual status display
The following drive states can be monitored using the operating panel after power-on:
● Servo off
● Actual speed
● Actual torque
● DC voltage
● Actual position
● Position following error
If servo enable signal is available, actual drive speed is displayed by default; otherwise, "S
OFF" (servo off) is displayed.
With p29002, you define which of the following drive operating status data is to be displayed
on the BOP.
Parameter
p29002
Note
Make sure you save p29002 after modification.
194
Range
Default
0 to 4
0
Unit
Description
-
0: Actual speed
1: DC voltage
2: Actual torque
3: Actual position
4: Position following error