10.2 Parameter list
Par. No.
Name
p1001
Fixed speed setpoint 1
Description: Sets a value for the fixed speed / velocity setpoint 1.
p1002
Fixed speed setpoint 2
Description: Sets a value for the fixed speed / velocity setpoint 2.
p1003
Fixed speed setpoint 3
Description: Sets a value for the fixed speed / velocity setpoint 3.
p1004
Fixed speed setpoint 4
Description: Sets a value for the fixed speed / velocity setpoint 4.
p1005
Fixed speed setpoint 5
Description: Sets a value for the fixed speed / velocity setpoint 5.
p1006
Fixed speed setpoint 6
Description: Sets a value for the fixed speed / velocity setpoint 6.
p1007
Fixed speed setpoint 7
Description: Sets a value for the fixed speed / velocity setpoint 7.
p1058
Jog 1 speed setpoint
Description: Sets the speed/velocity for Jog 1. Jogging is level-triggered and allows the motor to be incremen-
tally moved.
Note: The parameter values displayed on the BOP are integers.
p1082 *
Maximum speed
Description: Sets the highest possible speed.
Notice: After the value has been modified, no further parameter modifications can be made.
Note: The parameter values displayed on the BOP are integers.
The parameter applies for both motor directions.
The parameter has a limiting effect and is the reference quantity for all ramp-up and ramp-down times (e.g.
down ramps, ramp-function generator and motor potentiometer).
The range of the parameter is different when connect with different motors.
p1083 *
Speed limit in positive
direction of rotation
Description: Sets the maximum speed for the positive direction.
Note: The parameter values displayed on the BOP are integers.
p1086 *
Speed limit in negative
direction of rotation
Description: Sets the speed limit for the negative direction.
Note: The parameter values displayed on the BOP are integers.
p1115
Ramp-function generator
selection
Description: Sets the ramp-function generator type.
Note: Another ramp-function generator type can only be selected when the motor is at a standstill.
344
Min
Max
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 00.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
0.00
210000.000 100.00
0.000
210000.000 1500.00
0.000
210000.000 210000.
-210000.000
0.000
0
1
Factory
Unit
Data
Setting
type
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
0
rpm
Float
000
-
rpm
Float
210000.
000
0
-
I16
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T
IM
T
IM
T, U
IM
T, U
IM
T

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6

Table of Contents