Siemens Sinamics V90 Operating Instructions Manual page 68

Pulse train, uss/modbus interface
Hide thumbs Also See for Sinamics V90:
Table of Contents

Advertisement

General information
2.7 Technical data
Parameter
Vibration
Shock
Operation
Vibration
Product packag-
Vibration
ing
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be
1)
provided in accordance with the National Electrical Code and any additional local codes.
The V90 200 V servo drive has an overvoltage threshold of 410 V DC and an undervoltage threshold of 150 V DC; the
2)
V90 400 V servo drive has an overvoltage threshold of 820 V DC and an undervoltage threshold of 320 V DC.
SINAMICS V90 does not support motor overtemperature protection. Motor overtemperature is calculated by I
3)
protected by the output current from the drive.
Specific technical data
Order No. 6SL3210-5FE...
Frame size
Rated output current (A)
Max. output current (A)
Max. supported motor power
(kW)
Output frequency (Hz)
Cooling method
Outline dimensions (W x H x
D, mm)
Weight (kg)
Power loss
1)
Main circuit (W)
Regenerative resistor (W)
Control circuit (W)
Total (W)
Power supply
Voltage/frequency
Permissible voltage fluctua-
tion
Permissible frequency fluc-
tuation
66
Description
Operational area II
Peak acceleration: 5 g, 30 ms and 15 g, 11 ms
Quantity of shocks: 3 per direction × 6 directions
Duration of shock: 1 s
Operational area II
10 Hz to 58 Hz: 0.075 mm deflection
58 Hz to 200 Hz: 1 g vibration
2 Hz to 9 Hz: 3.5 mm deflection
9 Hz to 200 Hz: 1 g vibration
Quantity of cycles: 10 per axis
Sweep seed: 1 octave/min
10-4UA0
10- 8UA0 11-0UA0
FSAA
FSA
FSA
1.2
2.1
3.0
3.6
6.3
9.0
0.4
0.75
1.0
0 to 330
Self-cooled
60 x 180
80 x 180 x 200
x 200
1.800
2.500
2.510
12
29
32
17
57
57
32
32
35
61
118
124
3-phase 380 VAC to 480 VAC, 50/60 Hz
-15% to +10%
-10% to +10%
11-5UA0
12- 0UA0 13-5UA0
FSB
FSB
FSC
5.3
7.8
11.0
13.8
23.4
33.0
1.75
2.5
3.5
Fan-cooled
100 x 180 x 220
140 x 260 x 240
3.055
3.130
6.515
84
96
92
131
131
339
35
35
36
250
262
467
Operating Instructions, 04/2019, A5E36037884-007
t and
2
15-0UA0
17-0UA0
FSC
FSC
12.6
13.2
37.8
39.6
5.0
7.0
6.615
6.615
115
138
339
339
36
36
490
513
SINAMICS V90, SIMOTICS S-1FL6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6