Mounting The Motor - Siemens Sinamics V90 Operating Instructions Manual

Pulse train, uss/modbus interface
Hide thumbs Also See for Sinamics V90:
Table of Contents

Advertisement

Mounting

3.2 Mounting the motor

3.2.2
Mounting the motor
Personal injury and material damage due to motor falling down
Some motors, especially the 1FL609❑ are heavy. Motor falling down can cause serious
personal injury or material damage.
• The excessive weight of the motor should be considered and any necessary assistance
NOTICE
Damage to the motor due to liquid entering
If the liquid enters the motor, the motor may be damaged
• During motor installation or operation, make sure that no liquid (water, oil, etc.) can
• When installing the motor horizontally, make sure that the cable outlet faces downward
NOTICE
Damage to the absolute encoder due to the magnetic interference from the magnetic field
The magnetic interference from the magnetic field can cause a damage to the absolute
encoder.
• To avoid magnetic interference to the absolute encoder, keep the servo motor with an
Note
Using the eyebolts
The 1FL609❑ motor (90 mm shaft height) has two M8 screw holes for screwing in two
eyebolts. Lift the 1FL609❑ motor only at the eyebolts.
Eyebolts that have been screwed in must be either tightened or removed after mounting.
98
WARNING
required for mounting should be sought.
penetrate into the motor.
to protect the motor from ingress of oil or water.
absolute encoder at least 15 mm away from the devices that produce a magnetic field
stronger than 10 mT.
SINAMICS V90, SIMOTICS S-1FL6