Calculation formula for the electronic gear ratio
Examples for calculating the electronic gear ratio
Step
Description
1
Identify mechanism
2
Identify the encoder
resolution
3
Define LU
4
Calculate the travel
distance per load shaft
revolution
5
Calculate the electronic
gear ratio
6
Set parameters
p29012/p29013
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
Ball screw
Pitch of ball screw: 6 mm
Deduction gear ratio: 1:1
10000
1 LU = 1 μm
6/0.001 = 6000 LU
(1/6000)/(1/1) × 10000 = 10000/6000
10000/6000 = 5/3
7.3 Pulse train input position control (PTI)
Mechanism
Disc table
Rotary angle: 360
Deduction gear ratio: 1:3
10000
1 LU = 0.01
o
360
/0.01
= 36000 LU
o
o
(1/36000)/(1/3) × 10000 = 10000/12000
10000/12000 = 5/6