Power Derating - Siemens Sinamics V90 Operating Instructions Manual

Pulse train, uss/modbus interface
Hide thumbs Also See for Sinamics V90:
Table of Contents

Advertisement

2.7.2.3

Power derating

For deviating conditions (surrounding temperature > 40 °C or installation altitude > 1000 m
above sea level) the permissible torque/power must be determined from the following table.
Surrounding temperatures and installation altitudes are rounded off to 5 °C and 500 m
respectively.
Power derating as a function of the installation altitude and ambient temperature
Installation altitude above
sea level (m)
1000
1500
2000
2500
3000
3500
4000
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
Surrounding temperature in °C
< 30
30 to 40
1.07
1.00
1.04
0.97
1.00
0.94
0.96
0.90
0.92
0.86
0.88
0.82
0.82
0.77
General information
2.7 Technical data
45
50
0.96
0.92
0.93
0.89
0.90
0.86
0.86
0.83
0.82
0.79
0.79
0.75
0.74
0.71
55
0.87
0.84
0.82
0.78
0.75
0.71
0.67
77

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6

Table of Contents