Connecting Submersible Pump Motor Power For Remote Dispensers - Bennett Pacific eNVy 1000 Series Installation Manual

Remote dispensers (spec. 100 & spec. 200)
Table of Contents

Advertisement

Bennett Pacific eNVy Series Installation Manual

Connecting Submersible Pump Motor Power for Remote Dispensers

The remote dispensers require a submerged pump control relay box, such as Red Jacket or F.E. Petro across the line
starters. Check with Red Jacket or F.E. Petro for information on control relay boxes.
Termination of Field Wiring for Pump Motor Power of Remote Dispensers
WARNING:
CAUTION:
Follow the table shown below by locating the model number of the dispenser you are installing. The individual
product wires are identified by the colors used in this manual and on the wiring diagram. Connect the designated
wire to the power board terminal strip position as indicated in the chart.
1.
Connect the opposite end of the product control wire to the sub-pump relay box as below:
1
Product A - Connect the Red 14ga. wire to the Power Board as indicated in the diagram and the other
st
end to the control relay box for your 1st product.
2
nd
Product B - Connect the Blue 14ga. wire to the Power Board as indicated in the diagram and the other
end to the control relay box for your 2nd product.
3
Product C - Connect the Brown 14ga. wire to the Power Board as indicated in the diagram and the other
rd
end to the control relay box for your 3rd product.
4
th
Product D – Connect the Violet 14ga. wire to the Power Board as indicated in the diagram and the other
end to the control relay box for your 4th product.
Wiring Remote Sub-Pump Control Wires Directly to Power Supply Board or to the optional Junction Box
Model Number
Direct
1X11N1 or 1x12N2
Red to TS9
1x21M1 or 1x22M2
Red to TS9
or 1X22N2
1X22N1 or 1X24N2
Red to TS9
1X31B1 or 1X32B2
Red to TS9
1X31M1 or 1X32M2
Red to TS9
1X33N1 or 1X36N2
Red to TS9
1X41B1 or 1X42B2
Red to TS9
1X42B1 or 1X44B2
Red to TS9
1X42E1 or 1X44E2
Red to TS9
1X42M1 or 1X44M2
Red to TS9
1X44N1 or 1X48N2
Red to TS9
1X51B1 or 1X52B2
Red to TS9
1X52B1 or 1X54B2
Red to TS9
1X52E1 or 1X54E2
Red to TS9
1X56B1 or 1X56B2
Red to TS9
1X56E1 or 1X56E2
Red to TS9
1X53M1 or 1X56M2
Red to TS9
Wiring Installation
THE TERMINAL SEQUENCE DOES NOT NECESSARILY FOLLOW THE SEQUENCE OF THE
PRODUCTS. FOR EXAMPLE A TWO-PRODUCT DISPENSER CONNECTS TO THE "A"
PRODUCT RELAY OUTPUT AND THE "C" PRODUCT RELAY OUTPUT (NOT THE "B" AS
YOU MIGHT EXPECT).
Use a separate circuit breaker for each pump motor. Make sure the pump motor is never
on the same circuit breaker as any other power circuit for the dispenser.
Note: The color of the wire followed by the terminal number.
Blender Option: N = Non Blender, B = Blender, M = Mixer, E = Extended
1
st
Product
J-Box
Direct
Red to TS5
Red to TS5
Brown to TS17
Red to TS5
Brown to TS17
Red to TS5
Brown to TS17
Red to TS5
Blue to TS13
Red to TS5
Brown to TS17
Red to TS5
Brown to TS17
Red to TS5
Blue to TS13
Red to TS5
Blue to TS13
Red to TS5
Blue to TS13
Red to TS5
Blue to TS13
Red to TS5
Brown to TS17
Red to TS5
Blue to TS13
Red to TS5
Blue to TS13
Red to TS5
Blue to TS13
Red to TS5
Blue TS13
Red to TS5
Blue to TS13
2
nd
Product
J-Box
Direct
Brown to TS7
Brown to TS7
Brown to TS7
Blue to TS6
Brown to TS17
Brown to TS7
Violet to TS21
Brown to TS7
Blue to TS6
Brown to TS17
Blue to TS6
Brown to TS17
Blue to TS6
Brown to TS17
Blue to TS6
Brown to TS17
Brown to TS7
Blue to TS6
Brown to TS17
Blue to TS6
Brown to TS17
Blue to T6
Brown to TS17
Blue TS6
Violet to TS21
Blue to T6
Brown to TS17
23
Wiring Installation
3
rd
Product
J-Box
Direct
Brown to TS7
Violet to TS8
Brown to TS7
Brown to TS7
Brown to TS7
Violet to TS21
Brown to TS7
Violet to TS21
Brown to TS7
Brown to TS7
Brown to TS7
Violet to TS21
Violet to TS8
Brown to TS7
Violet to TS21
4
th
Product
J-Box
Violet to TS8
Violet to TS8
Violet to TS8
Violet to TS8

Advertisement

Table of Contents
loading

Table of Contents