6.5 Symptoms

If the product does not operate as usual, follow the symptoms table below. Speak to your Husqvarna customer
service if you cannot find the cause for the fault.
Symptoms
Cause
The product has diffi-
The guide wire is not put straight in a line
culty docking.
and correct distance from the charging sta-
tion.
The guide wire is not put in the slot in the
charging station plate.
The charging station is not on a level sur-
face.
The product operates
The time or the date in the product is not cor-
at the wrong time
rect.
The start and stop times for operating are in-
correct.
The product vibrates.
The cutting system is not in balance because
of damaged blades.
The cutting system is not in balance because
of too many blades in the same position.
Different thickness of blades are installed on
the product.
The product oper-
The product searches for the charging sta-
ates, but the blade
tion, or is moving to the starting point.
disc does not rotate.
The product operates
Grass or other object causes a blockage to
for shorter periods
the blade disc.
than usual between
The battery is at the end of its life cycle.
charges.
Blunt blades. More energy is necessary
when cutting the grass.
Mowing and charging
The battery is at the end of its life cycle.
times are shorter
than usual.
1440 - 004 - 24.03.2021
Action
Do a check of the installation of the charging
To examine where to put the
station. Refer to
guide wire on page 18
Make sure that the guide wire is put straight
in a line and put in the slot in the charging
station plate. Refer to
To install the guide
wire on page 20 .
Put the charging station on a level surface.
To examine where to put the charg-
Refer to
ing station on page 14 .
Set the time or date. Refer to
& date on page 30 .
Schedule settings. Refer to To
Change the
set the schedule on page 23 .
Examine the blades and screws and replace
Replace the
them if necessary. Refer to
blades on page 36 .
Do a check that only one blade is attached at
each screw.
Do a check if the blades are of different thick-
ness and replace if necessary.
Usual operation for the product. The blade
disc does not rotate when the product is
searching for the charging station.
Remove and clean the blade disc. Refer to
Chassis and blade disc on page 35 .
Replace the battery. Refer to
page 36 .
Replace the blades. Refer to
blades on page 36 .
Replace the battery. Refer to
page 36 .