6.4 Indicator lamp in the charging station

The indicator lamp in the charging station must show a solid or flashing green light for a correct installation. If not,
follow the instructions in the troubleshooting guide below.
Speak to your Husqvarna customer service for more information.
Light
Cause
Green solid light
Good signals
Green flashing light
The signals are good and
bled.
Blue flashing light
The boundary wire is not connected to the
charging station.
Damage in the boundary wire.
Red flashing light
Interference in the antenna of the charging
station.
Red solid light
Error in the circuit board or incorrect power
supply in the charging station. The error must
be corrected by an authorized service techni-
cian.
42 - Troubleshooting
Action
Usual operation of the product.
ECO mode is ena-
Usual operation of the product. Refer to
mode on page 29 .
Make sure that the boundary wire is correctly
installed in the charging station. Refer to
install the boundary wire on page 20 .
Find out where the damage is. Replace the
damaged section with new boundary wire.
Speak to your Husqvarna customer service.
Speak to your Husqvarna customer service.