Input Terminal Functions - GE Fuji Electric AF-300ES Instructions Manual

1/2 - 350 horsepower
Table of Contents

Advertisement

LCD
GRAPHIC
FUNCTION
DISPLAY
30
MTR POLES
* 31
32-41

INPUT TERMINAL FUNCTIONS

32
X1-X5 TERM
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
SETTING
DESCRIPTION
MOTOR POLES
The number of motor poles is set only for
the display of synchronous RPM. It has NO
effect on drive operation. Adjustable from
2 to 14 (even numbers only).
2 Poles
4 Poles
6 Poles
8 Poles
10 Poles
12 Poles
14 Poles
Example: When a 4 pole motor is operated at 60
Hz, the synchronous RPM display should read
60 x 120/4 = 1800 RPM.
Recall, synchronous speed (in RPM) = Hz x 120(Constant)
FUNCTION CODE BLOCK DISPLAY
This setting determines whether or not
Function Codes 32 through 41 will be displayed
and available for adjustment.
0:
Function Codes 32 through 41 NOT displayed.
1:
Function Codes 32 through 41 displayed.
X1 THROUGH X5 TERMINAL FUNCTIONS
This Function Code determines the functions
of the X1 through X5 contact inputs on the
terminal block. It is adjustable from 0000
to 2223. Each of the four digits has a
separate meaning as defined below.
X1 and X2 - function selected by 1st digit:
0 - - -
Multistep speed selection (four steps)
1 - - -
UP/DOWN control 1 (start from 0 Hz)
2 - - -
UP/DOWN control 2 (start from previous
setting).
X3 - function selected by 2nd digit:
- 0 - -
Multistep speed selection (8 steps using
X1, X2, and X3).
- 1 - -
Switching operation from line to drive
(50 Hz)
- 2 - -
Switching operation from line to drive
(60 Hz)
6-13
=
3600 RPM
=
1800 RPM
=
1200 RPM
=
900 RPM
=
720 RPM
=
600 RPM
=
514 RPM
FACTORY
SETTING
4
# poles
0
0000