Drive Fault
Drive Input/Output Display
Charge Lamp (LED)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
– OC1 - Acceleration overcurrent
– OC2 - Deceleration overcurrent
– OC3 - Constant speed overcurrent
– EF - Ground fault
– LU (LV) - Undervoltage
– OU1 - Overvoltage at accel
– OU2 - Overvoltage at decel
– OU3 - Overvoltage at constant speed
– FUS - DC Bus fuse failed
– OH1 - Drive overheat (Fins)
– OH2 - External alarm
– OH3 - Drive internal temperature
– Er1 - EE Prom malfunction
– Er2 - Communication error
– Er3 - CPU malfunction
– Er4 - Link error
– Er5 - Option malfunction
– Er6 - Drive error at start-up
– Er7 - Missing motor connection
– Forward
– Reverse
– Hld
– Bx
– X1 thru X5
– Y1 thru Y5
– Incoming reference voltages can be shown on LCD graphic display.
Lights when DC Link capacitor voltage is present.
2-6