Protective
Function
Operating
Detects Drive operating procedure error during Drive startup.
Proc. Error
FWD or REV connected to terminal CM at time of main power
being applied to Drive. Stop keypad in remote operation.
TUNING ERROR Er 6, Operating conditions that need to be reviewed:
Drive
Display
Protective
Function
Tuning error
Detects missing connection to the motor @ auto-tune.
TUNING ERROR Er 7, Operating conditions that need to be reviewed:
Drive
Display
Protective
Function
Prevent
Prevents OC-trip by ceasing frequency output at high current when
stall
torque limit is disabled and drive is accelerating, or when high impact
loads are applied to the motor. Second, by decreasing frequency
level when torque limit is activated and its value is being exceeded
during steady state operation and load acceleration.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Function Explanation
SEE MANUAL
Function Explanation
OPEN OUTPUT
MOTORCAP
BX ON
Function Explanation
8-8
LED
Alarm RY
Remarks
Display
(30A, B & C)
E r 6
LED
Alarm RY
Remarks
Display
(30A, B & C)
E r 7
LED
Alarm RY
Remarks
Display
(30A, B & C)
X
X