GE Fuji Electric AF-300ES Instructions Manual page 92

1/2 - 350 horsepower
Table of Contents

Advertisement

LCD
GRAPHIC
FUNCTION
DISPLAY
* 91
%R1 SET
* 92
%X SET
SPECIAL FUNCTIONS
93
DD FUNC 1
94
DD FUNC 2
95
DATA PRTC
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
SETTING
MOTOR #1 CALCULATED % PER UNIT RESISTANCE
0.00 TO
Percent of motor resistance.
50.00 %:
%R1 = R1 + Cable R x 100
R1 is motor resistance;
Cable R is resistance of cable between drive
and motor; V is rated motor voltage.
MOTOR #1 CALCULATED % PER UNIT IMPEDANCE
0.00 TO
Percent of motor impedance.
50.00 %:
%X = X1 + X2 x XM/ (X2 + XM) + Cable X x 100
X1, X2, XM are motor values;
Cable X is inductance of cable between drive
and motor; V is rated motor voltage.
DO NOT USE
DO NOT USE
DATA PROTECTION
Once the Function Codes have been set, the
data protection can be activated and prevent
any further changes.
0:
Not protected (changeable)
1:
Protected (change prevented)
Press >> and UP Key together to change Function
Code 95 to 1.
Press >> and DOWN Key together to change Function
Code 95 to 0.
Press FUNC DATA to store change in software.
DESCRIPTION
V/ (
3 x I)
V/ (
3 x I)
6-34
FACTORY
SETTING
%
%
0