C-## Frequency Control Functions; P-## Motor Data - GE AF-650 GP Operating Instructions Manual

General purpose drive high power 460/575/690v 125hp and above
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

How to Program

4.2.4 C-## Frequency Control Functions

Par. No. #
Parameter description
C-0#
C-01
Jump Frequency From [Hz]
C-02
Jump Speed From [RPM]
C-03
Jump Speed To [RPM]
C-04
Jump Frequency To [Hz]
C-05
Multi-step Frequency 1 - 8
C-2#
C-20
Jog Speed [Hz]
C-21
Jog Speed [RPM]
C-22
Jog Accel/Decel Time
C-23
Quick Stop Decel Time
C-24
Quick Stop Ramp Type
C-25
Quick Stop S-ramp Ratio at Decel. Start
C-26
Quick Stop S-ramp Ratio at Decel. End
C-3#
C-30
Frequency Command 2
C-34
Frequency Command 3

4.2.5 P-## Motor Data

Par. No. #
Parameter description
P-0#
P-01
Motor Poles
P-02
Motor Power [HP]
P-03
Motor Current
P-04
Auto Tune
P-05
Motor Cont. Rated Torque
P-06
Base Speed
P-07
Motor Power [kW]
P-09
Slip Compensation
P-1#
P-10
Slip Compensation Time Constant
P-2#
P-20
Motor Construction
P-3#
P-30
Stator Resistance (Rs)
P-31
Rotor Resistance (Rr)
P-33
Stator Leakage Reactance (X1)
P-34
Rotor Leakage Reactance (X2)
P-35
Main Reactance (Xh)
P-36
Iron Loss Resistance (Rfe)
P-37
d-axis Inductance (Ld)
AF-650 GP High Power Operating Instructions
Default value
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
0.00 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Linear
50 %
50 %
ExpressionLimit
ExpressionLimit
Default value
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Off
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Asynchron
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Type
-1
Uint16
67
Uint16
67
Uint16
4
-1
Uint16
-2
Int16
-1
Uint16
67
Uint16
-2
Uint32
-2
Uint32
-
Uint8
0
Uint8
0
Uint8
-
Uint8
-
Uint8
Type
0
Uint8
-2
Uint32
-2
Uint32
-
Uint8
-1
Uint32
67
Uint16
1
Uint32
0
Int16
-2
Uint16
-
Uint8
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-4
Uint32
-3
Uint32
-6
Int32
61