Table 4:
AF-300E$ Drive Ratings Efficiency and Watts Loss
Hp*
Catalog No.
Const
Trq
230 VAC - Three Phase
6KE$223F50X1A1
0.5
6KE$223001X1A1
1
6KE$223002X1A1
2
6KE$223003X1A1
3
6KE$223005X1A1
5
6KE$223007X1A1
7.5
6KE$223010X1A1
10
6KE$223015X1A1
15
6KE$223020X1A1
20
6KE$223025X1A1
25
6KE$223030X1A1
30
460 VAC - Three Phase
6KE$243001X1A1, B1
1
6KE$243002X1A1, B1
2
6KE$243003X1A1, B1
3
6KE$243005X1A1, B1
5
6KE$243007X1A1, B1
7.5
6KE$243010X1A1, B1
10
6KE$243015X1A1, B1
15
6KE$243020X1A1, B1
20
6KE$243025X1A1, B1
25
6KE$243030X1A1, B1
30
6KE$243035X1A1
6KE$243040X1A1
40
6KE$243050X1A1
50
6KE$243060X1A1
60
6KE$243075X1A1
75
6KE$243100X1A1
100
6KE$243125X1A1
125
6KE$243150X1A1
150
6KE$243200X1A1
200
6KE$243250X1A1
250
6KE$243300X1A1
300
* Verify the full load rated current of the motor to which the drive will be applied.
Note: In variable torque applications, Function Code 86 (Motor Hp Capability) needs to be changed to Set Drive Hp vs. Load Hp.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Output Current Output Power
Var
Const
Var
KVA
Trq
Trq
Trq
0.5
3
3
1.2
1
5
5
2
2
8
8
3.1
3
11
11
4.3
5
17
17
6.7
10*
25
29
9.9
15*
33
42
13
20*
46
55
18
25*
59
68
23
30*
74
80
29
87
34
1
2.5
2.5
2
2
3.7
3.7
2.9
3
5.5
5.5
4.4
5
9
9
7.2
10*
13
16.5
10
15*
18
23
14
20*
24
30
19
25*
30
37
23
30*
39
44
31
45
45
35
40*
45
52
35
50*
60
66
47
60*
75
77
59
75*
91
96
72
100*
112
124
89
125*
150
156
119
150*
176
180
140
200*
210
253
202
250*
304
304
242
300*
377
377
300
350*
415
415
330
Constant Torque
Efficiency %
KW
2K Hz
15K Hz
2K Hz
0.4
90.0
87.5
0.75
93.3
90.7
1.5
94.7
92.7
2.2
94.8
93.2
3.7
95.4
93.8
5.5
96.0
94.4
7.5
96.0
94.5
11
95.4
93.8
15
96.5
95.2
18.5
96.3
95.2
22
96.5
94.7
0.75
93.3
88.0
1.5
95.7
92.7
2.2
96.1
93.2
3.7
97.0
93.8
5.5
97.5
94.5
7.5
97.3
94.7
11
97.1
95.2
15
97.7
95.9
18.5
97.6
95.8
22
97.7
95.6
2K Hz
10K Hz
2K Hz
22
97.1
96.2
30
97.2
96.3
37
97.6
96.8
45
97.8
97.1
1000
55
98.0
97.2
1150
2K Hz
6K Hz
2K Hz
75
98.0
97.9
1500
90
98.1
97.9
1750
132
98.2
97.9
2050
160
98.1
97.8
2850
200
98.1
97.9
3500
220
98.3
98.0
3850
2-10
Variable Torque
Watts Loss
Watts Loss
15K Hz
15K Hz
40
50
50
70
80
110
115
150
170
230
220
310
415
300
415
685
510
685
720
530
720
890
690
890
1160
780
1160
50
90
65
110
85
150
110
230
140
300
400
200
400
525
315
525
610
340
610
780
450
780
970
510
970
10K Hz
650
850
850
1100
1050
900
1200
1150
1300
1250
1550
1500
6K Hz
1600
1850
2000
2000
2350
2300
3250
3150
4000
3800
4450
4300
Internal
DB
44
68
75
77
93
138
188
68
75
77
93
138
188
4-002