Compressor; Defrost - Danfoss AK-CC55 User Manual

Case/room controller (eev)
Hide thumbs Also See for AK-CC55:
Table of Contents

Advertisement

AK-CC55 Single Coil and Single Coil UI
Function
Values
S6 Low alarm limit 1
S6 High alarm limit 2
S6 Low alarm limit 2
S6 alarm delay
Alarm delay DI 1
Alarm delay DI 2
Alarm sensor S4% A
S6 alarm pull down delay
Alarm delay B
Use product sensor S6
0=No, 1=Yes
(1)
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.

Compressor

Table 17: Compressor
Function
Values
Min ON time
Min OFF time
Delay between comp.
Step control mode
1=Sequential, 2=Cyclic

Defrost

Table 18: Defrost
Function
Values
0=None, 1=Electrical,
Defrost method
2=Hot gas, 4=Air/Offcycle
Defrost stop limit A
Defrost start interval
Max. defrost time
Time staggering power-up
Drip off time
Fan start delay
Fan start temperature
0=OFF, 1=ON, 2=OFF at
Fan control during defrost
drip, 3=OFF at high temp
0=Time, 1=S5 sensor, 2=S4
Defrost stop method
sensor, 3=S5A and S5B
Pump down delay
Drain delay
Max. thermostat run time
0=OFF, 1=Monitoring,
Adaptive defrost mode
2=Skip day, 3=Skip day/
night, 4=Full adaptive
Hot gas injection delay
0=OFF, 1=ON, 2=Normal
Rail heat during defrost
control
Display delay after defrost
Fan stop temperature
(1)
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
© Danfoss | Climate Solutions | 2021.02
R-W
Code
1
2
3
4
1-2
A23
*
*
*
*
1-2
A24
*
*
*
*
1-2
A25
*
*
*
*
1-2
A26
*
*
*
*
1-2
A27
*
*
*
*
1-2
A28
*
*
*
*
1-2
A36
*
*
*
*
1-2
A52
*
*
*
*
1-2
A53
1-2
a01
*
*
*
*
(1)
R-W
Code
1
2
3
4
1-2
c01
*
*
*
1-2
c02
*
*
*
1-2
c05
1-2
c08
R-W
Code
1
2
3
4
1-3
d01
*
*
*
*
1-2
d02
*
*
*
*
1-2
d03
*
*
*
*
1-2
d04
*
*
*
*
1-2
d05
*
*
*
*
1-2
d06
*
*
*
*
1-2
d07
*
*
*
*
1-2
d08
*
*
*
*
1-2
d09
*
*
*
*
1-2
d10
*
*
*
*
1-2
d16
*
*
*
*
1-2
d17
1-2
d18
*
*
*
*
1-2
d21
*
*
*
*
(1)
1-2
d23
1-2
d27
*
*
*
*
1-2
d40
*
*
*
*
1-2
d41
*
*
*
*
5
6
7
8
9
Min. value Max. value Fact. value
*
*
*
-50.0 °C
*
*
*
-50.0 °C
*
*
*
-50.0 °C
*
*
*
0 min
*
*
*
0 min
*
*
*
*
*
0 min
*
*
*
*
*
0 %
*
*
*
0 min
*
*
0 min
*
*
*
0
5
6
7
8
9
Min. value Max. value Fact. value
*
0 min
*
0 min
*
0 s
*
1
5
6
7
8
9
Min. value Max. value Fact. value
*
*
*
*
*
0
*
*
*
*
*
0.0 °C
*
*
*
*
*
0 h
*
*
*
*
*
0 min
*
*
*
*
*
0 min
*
*
*
*
*
0 min
*
*
*
*
*
0 min
*
*
*
*
*
-50.0 °C
*
*
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0 min
*
0 min
*
*
*
*
*
0 h
*
*
*
*
*
0
*
0 min
*
*
*
*
*
0
*
*
*
*
*
5 min
*
*
*
*
*
-20.0 °C
BC364229688105en-000101 | 40
50.0 °C
-30.0 °C
50.0 °C
8.0 °C
50.0 °C
-30.0 °C
240 min
60 min
240 min
30 min
240 min
30 min
100 %
100%
240 min
90 min
240 min
30 min
1
0
30 min
0 min
30 min
0 min
999 s
5 s
2
2
4
1
50.0 °C
6.0 °C
240 h
8 h
360 min
45 min
240 min
0 min
60 min
0 min
60 min
0 min
10.0 °C
-5.0 °C
3
1
3
0
60 min
0 min
60 min
0 min
240 h
0 h
4
0
60 min
0 min
2
1
240 min
30 min
20.0 °C
0.0 °C