Miscellaneous - Danfoss AK-CC55 User Manual

Case/room controller (eev)
Hide thumbs Also See for AK-CC55:
Table of Contents

Advertisement

AK-CC55 Single Coil and Single Coil UI
Function
Values
Humidity alarm delay
Humidity ctrl. at defrost
0=No, 1=Yes
Humidity sensor - Min sig-
nal
Humidity sensor - Max sig-
nal
Humidity control
0=None, 1=Humidifier,
2=Dehumidifier
Humidity max. temp.
Humidity min. temp.
(1)
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.

Miscellaneous

Table 23: Miscellaneous
Function
Values
Delay of outputs at power-
up
DI1 Configuration
0=None, 1=DI status,
2=Door function, 3=Door
alarm, 4=Defrost start,
5=Main switch, 6=Night
setback, 7=Thermostat
band, 8=Alarm at closed,
9=Alarm at open, 10=Case
cleaning, 11=Forced cool-
ing, 12=Open blinds,
13=Coordinated defrost,
14=Forced closing,
15=Shutdown, 16=Light
control, 20=Leak detection,
21=Adaptive liquid control,
22=Valve driver, 23=Fan
alarm
Network address
Service pin
0=OFF, 1=ON
Access code 3
Temperature sensor type
0=Pt 1000, 1=PTC 1000,
2=NTC 5k, 3=NTC 10k
Max. hold time
Display air S4%
Pe Min range
Pe Max range
AO1 Min. voltage
AO1 Max. voltage
Refrigerant
0=Not seleted, 6=R13,
7=R13b1, 2=R22, 8=R23,
14=R32, 11=R114,
3=R134a, 12=R142b,
24=R170, 15=R227,
25=R290, 16=R401A,
18=R402A, 19=R404A,
21=R407A, 22=R407B,
20=R407C, 37=R407F,
49=R407H, 23=R410A,
32=R413A, 30=R417A,
31=R422A, 33=R422D,
34=R427A, 35=R438A,
40=R448A, 41=R449A,
48=R449B, 43=R450A,
44=R452B, 45=R454B,
9=R500, 4=R502, 10=R503,
17=R507, 36=R513A,
26=R600, 27=R600a,
5=R717, 28=R744,
46=R1233zdE, 38=R1234ze,
39=R1234yf, 47=R1234zeZ,
29=R1270, 42=R452A,
1=User defined display,
13=User defined
© Danfoss | Climate Solutions | 2021.02
R-W
Code
1
2
3
4
1-2
h27
1-2
h28
1-2
h29
(1)
1-2
h30
(1)
1-3
(1)
h31
1-2
h32
1-2
h33
R-W
Code
1
2
3
4
1-2
o01
*
*
*
*
1-2
(1)
o02
*
*
*
*
1-3
o03
*
*
*
*
(1)
1-2
o04
*
*
*
*
3-3
o05
*
*
*
*
1-3
o06
*
*
*
*
(1)
1-2
o16
*
*
*
*
1-2
o17
*
*
*
*
1-3
o20
*
*
*
*
(1)
1-3
(1)
o21
*
*
*
*
1-3
o27
*
*
*
*
(1)
1-3
o28
*
*
*
*
(1)
1-3
o30
*
*
*
*
(1)
5
6
7
8
9
Min. value Max. value Fact. value
*
0 min
*
0
*
0 RH%
*
h29
*
0
*
h33
*
-5.0 °C
5
6
7
8
9
Min. value Max. value Fact. value
*
*
*
*
*
0 s
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0 min
*
*
*
*
*
0 %
*
*
*
*
*
-1.0 Bar
*
*
*
*
*
6.0 Bar
*
*
*
*
0.0 V
*
*
*
*
o27
*
*
*
*
*
0
BC364229688105en-000101 | 42
240 min
60 min
1
0
h30
0RH%
100 RH%
100RH%
2
0
70.0 °C
70.0 °C
h32
2.0 °C
600 s
5 s
23
0
240
0
1
0
999
0
3
0
360 min
20 min
100 %
100%
5.0 Bar
-1.0Bar
200.0 Bar
12.0 Bar
o28
0.0V
10.0 V
10.0 V
49
0