Kubota RT120Q Operator's Manual page 182

Table of Contents

Advertisement

RT120Q Operator's Manual
500 Hour
Trencher
Adjust Headshaft Bearing
Adjust headshaft bearing every 500 hours.
To adjust:
1. Remove cover. Remove bolts attaching
trenching attachment motor to gearbox.
2. Remove bolt and washers in left end of
headshaft.
3. Support gearbox with hoist and slide it off
headshaft.
4. Install spacer (p/n 184-044) in place of
gearbox while checking bearings.
5. Replace bolt on end of headshaft.
6. Remove chain from headshaft sprocket.
7. Turn chain sprocket until headshaft sprocket turns.If it turns easily, remove a shim.
Plow
Change Plow Vibrator Oil
Hot parts may cause burns. Do not touch until
cool or wear gloves.
Change plow vibrator oil every 500 hours. If
normal operating temperature exceeds 100°F
(38°C), change plow vibrator oil every 250 hours.
Drain oil at drain plug (2). Replace plug and move
plow vibrator to horizontal position. Add MPL at fill until oil is halfway up sight glass (1). Refill capacity is 4
qts (3.8 L).
Service - 181