Maintenance And Test Instructions; Maintenance Schedule - LinMot P01-48-HP Series Installation Manual

Linear motors
Table of Contents

Advertisement

Installation Guide Linear Motors

6 Maintenance and test instructions

The person responsible for operating the motors must ensure that the prescribed maintenance work is
carried out. The following maintenance schedule is designed for use in hazardous areas (see section 2.1
Intended use).
The inspection cycles are subdivided below into the "Vertical" and "Horizontal" applications.
Mechanical maintenance work with pointed tools must be carried out outside the explosive
atmosphere.

6.1 Maintenance schedule

Vertical
Application
Application
10 million
movement cycles
movement cycles
each
or
1200 friction
kilometres
50 million
movement cycles
movement cycles
each
or
6000 friction
3000 friction
kilometres
Page 36 / 47
Horizontal
What
Bearing clearance
Abrasion
Ease of movement
Slider
5 million
Electrical
Connection
each
or
Water cooling
600 friction
kilometres
Tightness
Case
External bearings
and wipers
Slider
Electrical
Connection
25 million
Water cooling
each
or
Tightness
kilometres
Case
Ease of movement
P01-48-HP EX protected
Action
Check for bearing clearance, abrasion and ease of
movement.
The bearing must be replaced if there is clear
evidence of wear or sluggishness of the slider.
Check that the slider surface is clean and not
scratched. Scratched sliders must be replaced,
otherwise clean sliders.
Tighten the plug screw connection.
(Tightening torque 5 Nm according to section
"Electrical connection of the motor")
Check whether the cooling circuit is permanently
guaranteed.
Check whether the external bearings are still firmly
screwed onto the stator without a gap.
(Tightening torque 6 Nm according to section
"Mounting the motor")
Ensure that no thick layers of dust form on the
housing and external bearings. Large deposits
disturb the heat radiation.
Replace the plastic bearing and the wiper on both
sides (see section "Mounting the motor").
Check that the slider surface is clean and not
scratched. Scratched sliders must be replaced,
otherwise clean sliders.
Tighten the plug screw connection.
(Tightening torque 5 Nm according to section
"Electrical connection of the motor")
Check whether the cooling circuit is permanently
guaranteed.
Check whether the external bearings are still firmly
screwed onto the stator without a gap.
(Tightening torque 6 Nm according to section
"Mounting the motor")
Ensure that no thick layers of dust form on the
housing and external bearings. Large deposits
disturb the heat radiation.
If friction is noticeable during the movement of the
rotor, the motor must be switched off immediately.
Check the alignment of the load guide and the rotor.
ENG
NTI AG / LinMot

Advertisement

Table of Contents
loading

Table of Contents