Performance Characteristic; Thermal Behavior; Internal Temperature Monitoring - LinMot P01-48-HP Series Installation Manual

Linear motors
Table of Contents

Advertisement

Installation Guide Linear Motors
Artikel
PB01-48x25-80-E-SSC
PB03-48x25-80-E-SSC

3.5 Performance characteristic

With the design software "LinMot Designer" software (download from the link
https://linmot.com/download/linmot-designer/), the key data corresponding to the required load situation,
such as peak force, nominal force, or maximum speed, can be calculated and presented. The motor
operating temperature can also be determined. This must be verified in the real application.

3.6 Thermal behavior

3.6.1 Internal temperature monitoring

Setting the motor internal temperature monitoring:
Operation in temperature class T4
The temperature monitoring configuration can be left in the default settings.
The nominal sensor operating temperature is 90°C. At 95 °C a warning is given and at 100 °C the drive goes
into error state. The LinMot-Designer program provides concrete information on the motion designs.
Logging in is necessary to view these parameters.
User-ID:
Password: without (in default state)
Page 16 / 47
Beschreibung
Bearing for PS01-48x...-SSC (Stainless)
Bearing for PS01-48x...-SSC (Stainless)
«SERVICE»
T4 Max. Sensor Temperature (Default Setting)
P01-48-HP EX protected
ENG
Art-Nr.
0150-4190
0150-4191
NTI AG / LinMot

Advertisement

Table of Contents
loading

Table of Contents