1.4.2
CC-Link Ver. 2
The FR-A8NC is compatible with CC-Link Ver.2.
When using the CC-Link Ver.2 setting with the
FR-A8NC, the master station needs to be
compatible with the CC-Link Ver.2.
For CC-Link Ver.2, double, quadruple and
octuple settings can be used to increase the
remote register (RWr/w) points.
Master station (CC-Link Ver.1)
CC-Link Ver.1
CC-Link Ver.2
setting
setting
Communication
Communication
enabled
disabled
("RUN" LED flickers)
Master station (CC-Link Ver.2)
CC-Link Ver.1
setting
Communication
enabled