Pr.340
Pr.79
setting
setting
0 (initial
External operation mode
value)
1
PU operation mode
2
External operation mode
0
3, 4
External/PU combined operation mode
6
External operation mode
X12 (MRS) signal ON: external operation
mode
7
X12 (MRS) signal OFF: external operation
mode
0
NET operation mode
1
PU operation mode
2
NET operation mode
3, 4
External/PU combined operation mode
*2
1
6
NET operation mode
X12 (MRS) signal ON: NET operation mode
7
X12 (MRS) signal OFF: external operation
mode
Operation mode at power ON or
power restoration
Operation mode switchover
Switching among the External, PU, and NET operation mode is
*1*4
enabled.
PU operation mode fixed
Switching between the External and Net operation mode is
*4
enabled.
Switching to the PU operation mode is disallowed.
Operation mode switching is disallowed.
Switching among the External, PU, and NET operation mode is
*4
enabled while running.
Switching among the External, PU, and NET operation mode is
*1*4
enabled.
External operation mode fixed (Forcibly switched to External
operation mode.)
Same as when Pr.340 = "0"
INVERTER SETTING
4
35