8.3
Program example for setting the operation commands
The following program gives a forward command and middle speed command to station 1 inverter
X0
X0F
0
M0
X20
7
11
Y100F
b15
0
0
0
0
Run command
b0: Forward rotation command
b1: Reverse rotation command
b2: High-speed operation command (terminal RH function)
b3: Middle-speed operation command (terminal RM function)
b4: Low-speed operation command (terminal RL function)
b5: Jog operation selection 2
*1
These signals are initial values. You can change input signals using Pr.180 to Pr.189 (input terminal function selection). Note that
some of the signals do not receive a command from the programmable controller depending on the setting.
(For details, refer to the FR-E800 Instruction Manual (Function).)
*2
The signals are fixed. They cannot be changed using parameters.
86
PROGRAMMING EXAMPLES
X1
SW80.0
b7
0
0
0
0
0
0
0
0
[Run command]
Middle speed
M0
Y1000
Y1003
END
Y1000
b0
1
0
0
1
Forward rotation
b6: Second function selection
b7: Current input selection (AU)
b8: No function (terminal NET X1 function)
b9: Output stop (terminal MRS function)
b10: No function (terminal NET X2 function)
b11: Inverter reset (terminal RES function)
Check the data link status of the station 1
Forward rotation command (RY00)
Middle speed operation command (RY03)
RY0F to RY00
One station
RY1F to RY10
1: ON
0: OFF