Program Example For Setting The Operation Commands - Mitsubishi Electric 800 Series Instruction Manual

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

8.3

Program example for setting the operation commands

The following program gives a forward command and middle speed command to station 1 inverter
X0
X0F
0
M0
X20
7
11
Y100F
b15
0
0
0
0
Run command
b0: Forward rotation command 
b1: Reverse rotation command 
b2: High-speed operation command (terminal RH function) 
b3: Middle-speed operation command (terminal RM function) 
b4: Low-speed operation command (terminal RL function) 
b5: Jog operation selection 2 
*1
These signals are initial values. You can change input signals using Pr.180 to Pr.189 (input terminal function selection). Note that
some of the signals do not receive a command from the programmable controller depending on the setting.
(For details, refer to the FR-E800 Instruction Manual (Function).)
*2
The signals are fixed. They cannot be changed using parameters.
86
PROGRAMMING EXAMPLES
X1
SW80.0
b7
0
0
0
0
0
0
0
0
[Run command]
Middle speed
M0
Y1000
Y1003
END
Y1000
b0
1
0
0
1
Forward rotation
b6: Second function selection 
b7: Current input selection (AU) 
b8: No function (terminal NET X1 function) 
b9: Output stop (terminal MRS function) 
b10: No function (terminal NET X2 function) 
b11: Inverter reset (terminal RES function) 
Check the data link status of the station 1
Forward rotation command (RY00)
Middle speed operation command (RY03)
RY0F to RY00
One station
RY1F to RY10
1: ON
0: OFF