Mitsubishi Electric 800 Series Instruction Manual page 49

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Speed setting using
Pr.37 and Pr.53
Not used
With
• Relationship between the start command and sign (Pr.541 = "1")
Start command
Sign of the frequency command
+
Forward rotation
-
+
Reverse rotation
-
NOTE
• When Pr.541 = 1 (with sign)
When EEPROM write is specified with the RYE, write mode error (error code H01) will occur. When concurrent execution of
both RYD and RYE is enabled (when a value other than 0 is set in Pr.544) and both RYD and RYE are turned on, RYD has
precedence. When power is turned on (inverter reset), the initial setting status of the sign bit is "positive" and the set frequency
is "0 Hz". (The motor does not operate at the frequency set before turning OFF the power (inverter reset).) When set frequency
is written with the instruction code of HED and HEE, the sign of the frequency command is not changed.
48
INVERTER SETTING
Pr.541
Sign
setting
0
Not used
0 to 59000
-32768 to 32767
1
With
(two's complement)
0
Not used
0 to 65535
-32768 to 32767
1
With
(two's complement)
Setting range
Actual run command
Forward rotation
Reverse rotation
Reverse rotation
Forward rotation
Actual frequency command
0 to 590.00 Hz
-327.68 to 327.67 Hz
It depends on Pr.37, Pr.53
(in 1 or 0.1 increments)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a8nc e

Table of Contents