Addressing Cells

Each cell has a serial number (S/N) marked on the cell. This is an eight digit hexadecimal
number. It is also known as the cell ID. Each cell ID must be matched with a cell address. In
the tank/hopper example, the addresses would be 1-4. In the truck scale example, the
addresses would be 1-8.
Enter the SETUP menu by pressing SHIFT+RED_KEY.
1.
Press ENTER again to get to SETUP MENU #1.
2.
Press 8 and ENTER to set number of scales and cells.
3.
1. USA=XXX
2. NSC=XXX
3. LFT=XXX
4. OIML=N/A
5. TIME=XX
Enter Selection:
Enter number of scales and press ENTER.
4.
Enter number of cells and press ENTER. The addressing menu will appear.
5.
1. CELL 1
2. CELL 2
3. CELL 3
4. CELL 4
Enter Selection: 0
Press a cell number, and then ENTER to be prompted for the associated scale number
6.
followed by the cell ID.
If the cell is found, the 225D will display "CELL RESPONDED". If the cell does not
7.
respond the 225D will sound an error beep and display "—FAILED—". If the cell is
disconnected, then this error can be ignored.

End Nodes

The 225D indicator also needs to know where the scale starts and ends. The START NODE is
the cell that connects to the 225D. The END node is last cell in the daisy chain. In the
tank/hopper example, the START node is #1 and the END node is #2. In the truck scale
example, the START node is #4 and the END node is #6.
To set the nodes:
Press the END NODES soft key.
1.
The 225D will display "WHICH CELL CONNECTS TO THE 225? ".
2.
In the previous examples the user would enter 1 (tank/hopper) or 4 (truck) and ENTER.
3.
The 225D will display "WHICH CELL IS THE LAST IN THE LOOP? ".
4.
In the previous examples the user would enter 2 (tank/hopper) or 6 (truck) and ENTER.
5.
12
SETUP MENU #1
CELL TO SCALE ASSIGNMENTS
SCALE=1 ID=1D7A173F START
SCALE=1 ID=0EB0EBFF END
SCALE=1 ID=18B8783F
SCALE=1 ID=09C99FFF
8200-0753-0M Rev A  225D Weight Digital Indicator
6. CLR TARE=XXX
7. CLEAR ID=XXX
8. SCALES=X CELLS=X