Cardinal 225D SmartCell Installation And Technical Manual page 24

Hide thumbs Also See for 225D SmartCell:
Table of Contents

Advertisement

COMMUNICATION ERROR BETWEEN LOAD CELLS X AND Y
NO WEIGHT
-------
COMMUNICATION ERROR BETWEEN
LOAD CELLS 1 AND 3
Probable Cause
There is a loss of
communication between load
cells.
LOAD CELL X, Y, Z NOT RESPONDING
NO WEIGHT
-------
LOAD CELL 2 NOT RESPONDING
Probable Cause
The 225D cannot detect the
exact communication problem
with the unresponsive load
cell.
LOAD CELL X DAMAGED
NO WEIGHT
-------
REPLACE LOAD CELL 2
Probable Cause
There is irreparable internal
damage to the load cell.
18
ID
COUNT
 Check that cable is connected correctly.
 Check cable for damage.
 Verify that connector is clear of debris.
 Check load cell COM ports on both load cells.
ID
COUNT
 Check that cable is connected correctly.
 Check cable for damage.
 Verify that connector is clear of debris.
 Potentially dead load cell.
ID
COUNT
Replace load cell.
8200-0753-0M Rev A  225D Weight Digital Indicator
lb
G
Items to Check
lb
G
Items to Check
lb
G
Items to Check











Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents