LOAD CELL ID 8F07E8F HAS NO ADDRESS
NO WEIGHT
-------
LOAD CELL ID 8F07E8F HAS NO ADDRESS
Probable Cause
A load cell is responding, but
it is not addressed in the
system.
LOAD CELL ADDRESS X NOT ASSIGNED TO SCALE
NO WEIGHT
-------
LOAD CELL ADDRESS 1 NOT ASSIGNED
TO SCALE
Probable Cause
A load cell has not been
assigned to a scale.
LOW VOLTAGE DETECTED ON LOAD CELL X, Y, Z
NO WEIGHT
-------
LOW VOLTAGE ON LOAD CELL 2,4,6
Probable Cause
Low power on a load cell.
Load cells at the end of the
CAN daisy chain are most
susceptible to low voltage
errors because of voltage
drop along the cable.
20
ID
COUNT
Go to the addressing menu and assign the load cell ID to
an address.
ID
COUNT
Go to addressing menu and assign a scale to the load
cell.
ID
COUNT
 Too many load cells on the chain.
 Check that cable is connected correctly.
 Check cable for damage.
 Verify that connector is clear of debris.
 Check 225D indicator power supply.