External Outputs - Panasonic HG-T Series User Manual

Thru-beam type digital displacement sensor
Hide thumbs Also See for HG-T Series:
Table of Contents

Advertisement

Setting method
Setting item
External input (EXT.IN)

7.2.4 External Outputs (

This function allows you to select a combination of signals to be output from external output 1,
output 2, and output 3 from five types. This product is equipped with an alarm signal output
function. When the sensor head does not operate correctly, alarm signals enable you to take
prompt action. It is also equipped with a signal (hold output) that allows you to check the hold
status. Therefore, hold operation status can be grasped in real time.
Set value
3-value
2-value
Logic
Logic 2
WUME-HGT-6
Preset / Reset / Trigger (P/R/T)
Bank A / Bank B / Preset (BANK/P)
Bank A / Bank B / Reset (BANK/R)
Bank A / Bank B / Trigger (BANK/T)
Preset / Trigger / Laser emission stop (P/T/L)
)
Display
This function uses OUT1, OUT2, and OUT3 to control ON / OFF
according to the judgment value.
This function uses OUT1 and OUT2 to control ON / OFF according to
the judgment value.
OUT3 is used to control ON / OFF when an alarm (error) occurs.
This function uses OUT1 and OUT2 to control ON / OFF as logical
value representation according to the judgment value.
OUT3 is used to control ON / OFF when an alarm (error) occurs.
OUT1 is used to control ON / OFF when all the connected controllers
are in GO state.
OUT2 is used to control ON / OFF when the master unit is in GO state.
OUT3 is used to control ON / OFF when an alarm (error) occurs on any
of the connected controllers.
7.2 Advanced Settings (
Set value
Function
)
Default value
P/R/T