Setting a LOW set value directly during measurement
1.
Press the
(green), and the LOW set value appears in the digital display section / MAIN (white).
2.
Press the
decrease the numerical value.
3.
Press the
● If you take no action for 5 seconds, the screen will automatically return to the base screen and
the setting will be finalized.
6.4.3 Hysteresis (
If the measured object vibrates in the vicinity of the HIGH/LOW set value, the judgment value
may fluctuate, resulting in unstable operations. Increasing the value of hysteresis makes
operations stable.
If hysteresis is "0"
The judgment value (JUDGE.V) fluctuates in the vicinity of the HIGH set value (or LOW set
value), making judgment output unstable.
(In the following timing chart, external output is set to "3VAL" and output operation is set to
"N.O.".)
WUME-HGT-6
key in the base screen. "LO.SET" appears in the digital display section / SUB
/
key to change the digit position. Press the
key to finalize the setting.
)
6.4 Basic Settings (
/
key to increase or
)
6-17