● The following states are judged to be indeterminate states and displayed as "
• Full light entry state
• State in which more than one edge is detected (such as detection of transparent body)
If auto edge detection mode is set, the base position will be switched according to the direction
(TOP or BOTTOM side) in which the measured object enters the measurement area of the
sensor head, causing the HIGH and LOW set values to be switched.
Example of switching between HIGH and LOW set values
When the measured object enters the measurement area from the TOP side
When the measured object enters the measurement area from the BOTTOM side
● When the measured object enters the measurement area from the TOP side, LOW set value
2.0 mm is used. When the measured object enters the measurement area from the BOTTOM
side, LOW set value 2.0 mm is switched to HIGH set value 8.5 mm.
● When the measured object enters the measurement area from the BOTTOM side, HIGH set
value 7.0 mm is used. When the measured object enters the measurement area from the
TOP side, HIGH set value 7.0 mm is switched to LOW set value 3.5 mm.
● If auto edge detection mode is set, the upper limit for measured values is 10.5 mm.
5.4.2 Edge Detection Mode (
When the direction in which the measured object enters the measurement area of the sensor
head is specified as the TOP or BOTTOM side, this mode measures the distance from the TOP
or BOTTOM side of the measurement area to the edge of the measured object.
WUME-HGT-6
)
5.4 Operation Mode
".
5-23