External I/O - Panasonic GP-X Series User Manual

Digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

1.4 External I/O

Terminal
Indication
No.
1
LO
2
GO
3
HI
Output
4
COM
5
ALARM
6
STROBE
7
INT P OUT
8
Analog
ANALOG
output
9
10
0 SET
11
MEMORY
12
13
Input
COM
14
TIMING
15
RESET
16
INT P IN
17
0V
Power
supply
18
24V DC
10 11 12 13 14 15 16 17 18
Name
LO output
GO output
HI output
Common
Alarm output
Strobe output
Interference
prevention output
GND
Analog ground
OUT
Analog voltage output
Zero setting input
1
Memory switch 1
2
Memory switch 2
Common
Timing input
Reset input
Interference
prevention input
Power supply 0V
Power supply 24V DC
1 2 3 4 5 6 7 8 9
Description
A signal is output if the measurement
is smaller than the lower limit value.
A signal is output if the measurement is
between the upper and lower limit values.
A signal is issued if the measurement
is larger than the upper limit value.
NPN output type: 0V
Common
PNP output type: 24V
A signal is output if an error occurs.
An internal trigger outputs for
measurement interval.
A signal is sent to another controller for
removal of effects caused by interference.
The measurement is output in an
analog voltage.
The current detection position is forcibly
zeroed (to become a reference position).
One among four settings is called up
from the internal memory to replace
the current setting with it.
NPN output type: 0V
Common
PNP output type: 24V
Measurement begins.
Temporarily finishes the holding interval.
With a signal sent from another controller,
effects caused by interference are removed.
Supply power.
13