Standard difference (
For each slave unit, the difference between the measured value of the master unit and that of
the slave unit is used as the calculated value.
This application causes each slave unit to output judgment results.
The measured value of slave unit 2 minus the measured value of the master unit is used as the
calculated value of slave unit 2.
● The master unit performs judgment operations as a single unit that does not perform
calculations.
● The master unit cannot use the hold function.
● The response time for judgment output is the respective response times of the master unit
and slave unit plus 3 ms.
Thickness/width (
A measured object is placed between two sensor heads to calculate the thickness or width of
the object.
Calculated value = Measured value of master unit + Measured value of slave unit 1
● The slave unit nearest the master unit does not output judgment results. (Always OFF)
WUME-HGT-6
7.3 Calculation Settings (
)
)
)(For Master Units Only)