7.3 Calculation Settings (
The normal measured value (NORM.V) is displayed in the digital display section / MAIN
(white) of the slave unit.
Minimum value (
The smallest measured value of the measured values of the master unit and slave units is used
as the calculated value.
The minimum measured value of the master unit is used as the calculated value of the master
unit.
● None of the connected slave units outputs judgment results. (Always OFF)
● The response time for judgment output is the respective response times of the master unit
and slave unit plus 3 ms.
Average value (
The average value of the measured values of the master unit and slave units is used as the
calculated value.
([Master unit] + [Slave unit 1] +...+ [Slave unit n]) ÷ (1 + n) is used as the calculated value of the
master unit.
Where, n is the number of slave units
● None of the connected slave units outputs judgment results. (Always OFF)
● The response time for judgment output is the respective response times of the master unit
and slave unit plus 3 ms.
7-56