Emergency Features; 24-Hour Alarm Buttons; Panic Button; Fire Button - 2gig Technologies EDGE User Manual

Security & smart home system
Hide thumbs Also See for EDGE:
Table of Contents

Advertisement

2 . Review the Alarms list . Then tap CLEAR
ALARM HISTORY .

Emergency Features

24-Hour Alarm Buttons

Three 24-hour alarm buttons can be shown or hidden by
the installer on the Control Panel's touchscreen: Panic,
Fire, and Emergency .
You can open the following screen by pressing the
button on the Control Panel:

Panic Button

When activated, the system immediately goes into the alarm state. Depending on how the system is configured, the
Control Panel emits a loud, patterned warning siren or sets off a silent panic alarm with no siren . The system also
transmits a police report to the Central Station .
NOTES:
1
Consult your installer to determine if the Police Emergency Key is configured to sound an audible alarm or a
silent panic alarm .
2
Consult your installer to determine if the 2-Way Voice feature is enabled on the system . If enabled, setting off
the Panic alarm gives operators at the Central Station the ability use the Control Panel's built-in speaker and
microphone to converse with people on the premises .
3
Consult your installer to determine if the Silent Panic/Burglary Listen Only feature is enabled on the system .
If enabled, setting off the Panic alarm gives operators at the Central Station the ability to use the Control
Panel's built-in microphone to listen . If the panic alarm is sent, the operator can only listen . For your
protection, the operator will not be heard at the panel .

Fire Button

When activated, the system immediately goes into the alarm state . The Control Panel emits a loud, patterned warning
siren that is in compliance with ANSI S3.41 Temporal-3 Fire Alarm Signal and continues to sound until the system is
disarmed (see
Disarming the
Report to the Central Station .
NOTES:
1
Consult your installer to determine how the Fire Bell Cutoff Time is configured on your system. The time
can be configured to last 4 minutes, 8 minutes, 12 minutes, 16 minutes, or Unlimited (no cutoff) . The default
setting is four (4) minutes .
2
If Smart Areas is enabled the Fire Button will create a global alarm in all Smart Areas . The alarm must be
acknowledged/cleared in each Smart Area .
System, pg 26) or the Fire Bell Cutoff Time expires . The system also transmits a Fire
Alarms Screen
24-Hour Alarm Buttons
33
Copyright © 2021 Nortek Security & Control LLC