Dual Tech Switch-mount Occupancy Sensor
Overview
The Elaho Dual Tech Switch-mount Occupancy Sensor is a switch station with
a built-in sensor that uses passive infrared (PIR) and acoustic detection to
provide reliable occupancy and vacancy sensing for lighting control.
Each button is backlit by both blue and amber LEDs to show changes in status.
The sensor provides a 180 degree field of view with up to 45 feet (13.7 m)
radius for large motion detection.
This document guides you through the installation and local configuration and
setup of the Dual Tech Switch-mount Occupancy Sensor.
Custom Configuration
For more information about the custom configuration options available using
ElahoAccess, reference the ElahoAccess Mobile App integrated help system.
Note:
function selection switch is set to Custom (middle position). Reference
Function switch on page 11
Main Offic e
Squamish, BC, Canada
n
Email
info@echoflexsolutions.com
© 2018 Echoflex Solutions, Inc.
8186M2187
Revision A
Released 2018-09
n
n
Settings made using ElahoAccess are applied only when the
Toll Free +888 324 6359
n
W eb
echoflexsolutions.com
n
Echoflex intends this document to be provided in its entirety.
n
The Dual Tech Switch-mount Occupancy
Sensor is available in one and two-button
models, and is available with white,
black, cream, or gray wall plate.
.
Phone +778 733 0111
n
Product information and specifications subject to change.
n
Fax +604 815 0078
n

Advertisement

Table of Contents
loading

Summary of Contents for ETC Echoflex Dual Tech

  • Page 1 Echoflex Installation Guide Dual Tech Switch-mount Occupancy Sensor Overview The Elaho Dual Tech Switch-mount Occupancy Sensor is a switch station with a built-in sensor that uses passive infrared (PIR) and acoustic detection to provide reliable occupancy and vacancy sensing for lighting control. The Dual Tech Switch-mount Occupancy Sensor is available in one and two-button models, and is available with white,...
  • Page 2: Prepare For Installation

    When operating in PIR only modes, the sensor must have an • unobstructed view of the room. Do not mount behind or near tall cabinets, shelves, hanging light fixtures, etc. Do not install the sensor within eight feet from an HVAC airflow •...
  • Page 3: Wire Specification

    Echoflex Installation Guide Switch-mount Occupancy Sensor Wire Specification ® The Dual Tech Switch-mount Occupancy Sensor utilizes EchoConnect power and for data communications with an Elaho control system. EchoConnect is a bidirectional protocol that uses one pair of wires (data + and data -) for both data and power.
  • Page 4: Installation

    Echoflex Installation Guide Switch-mount Occupancy Sensor Installation Installation should follow all local codes and standard electrical practices. Note: NEC Class 2 product to be wired in accordance to NEC Article 725 and local jurisdiction requirements. The switch box should be installed plumb and square for best results. Ensure that the switch box is clean and free of obstructions and that all wiring is installed correctly.
  • Page 5 Echoflex Installation Guide Switch-mount Occupancy Sensor Rotary and DIP Switches Rotary and DIP switch settings are accessible on the rear of the station. Set Space and Address The two rotary switches provide for assignment of the sensor space and address. Each sensor must be set to a unique station address for the assigned space.
  • Page 6 Echoflex Installation Guide Switch-mount Occupancy Sensor DIP Switch Settings DIP switches provide for designation of “Off” functionality, the ability to disable amber button LEDs, and the ability to restore the sensor to its factory defaults. Switch # 1-button Dual Tech Switch-mount Occupancy Sensor only When set to On, and the function switch is set to Preset, enables •...
  • Page 7 Echoflex Installation Guide Switch-mount Occupancy Sensor Note: When the sensor Function switch is set to Custom, only DIP switch number 8 applies. All other DIP switch settings are ignored. Station Configuration on page 11 Reference for local configuration settings on your Dual Tech Switch-mount Occupancy Sensor. Reference the ElahoAccess Mobile App integrated help system for details about custom configuration using the ElahoAccess Interface.
  • Page 8 Echoflex Installation Guide Switch-mount Occupancy Sensor Remove the button lens. Using the pads of your thumb, press on the lens • and slide the lens left, toward the hinge points. Once the lens is removed, remove the existing legend and insert a custom legend. Replace the lens onto the button by aligning the grooves of the lens to the button, then sliding the lends in place starting at the hinge.
  • Page 9: Power Up And Test

    Echoflex Installation Guide Switch-mount Occupancy Sensor Install the Wall Plate The wall plate is secured to the station with built-in magnets. Align the top of the wall plate to the station and angle the bottom approximately 20 degrees. Hook the top of the wall plate to the tabs located on the station electronics assembly.
  • Page 10 Echoflex Installation Guide Switch-mount Occupancy Sensor PIR (only) Detection When acoustic detection is disabled (DIP switch 6 set to On), the following logic is used: When the space is vacant, PIR detection and manual control can switch • the state to occupied. When the space is occupied, PIR detection and manual control can •...
  • Page 11: Station Configuration

    Echoflex Installation Guide Switch-mount Occupancy Sensor Station Configuration The Dual Tech Switch-mount Occupancy Sensor has on-board switch and button settings that are available from the front of the station when it is installed and the wall plate is removed. Program Mode Press and hold the [Walk Test] button 3 seconds to enter Program Mode...
  • Page 12 Echoflex Installation Guide Switch-mount Occupancy Sensor When a preset is active, the button LED lights blue to indicate its active state. If preset levels are altered while the preset is still active, the related button LED will return to its default state, either off or amber. Reference Rotary and DIP Switches on page 5 Use Off Functionality (2 button Switch-mount Sensor only)
  • Page 13 Echoflex Installation Guide Switch-mount Occupancy Sensor Zone Toggle Functionality While the Function switch is set to Zone, the station allows you to toggle the zone on and off. The controlled zone level raises to full or toggles off using a Station 1/2 or 2 second fade time, depending on the station type.
  • Page 14 Echoflex Installation Guide Switch-mount Occupancy Sensor Program Zone Start Note: The zone that is configured to the button control(s) is also the zone that will be activated at full with occupancy detection and deactivated with vacancy detection. Set the station Function switch to its lowest position of Zone. Press and hold the [Walk Test / Program Mode] button for three seconds to enter Program Mode.
  • Page 15 Echoflex Installation Guide Switch-mount Occupancy Sensor Station Functionality One Button Switch-mount Sensor The one button switch-mount sensor offers control of a single preset or zone as determined by the Function switch setting. Factory Defaults The one button switch-mount sensor ships from the factory in the following default settings: Rotary and Rotary switches are set to Address 1, Space 1.
  • Page 16 Echoflex Installation Guide Switch-mount Occupancy Sensor Zone In Zone mode, an occupancy detection event activates the zone that is configured to button 1 at full, and the vacancy detection event deactivates the Zone (set to 0%). The one button switch-mount sensor supports the following button actions: Double-tap the button to toggle the preset using a 1/2 second fade time.
  • Page 17 Echoflex Installation Guide Switch-mount Occupancy Sensor Double-tap the button to toggle the preset using a 1/2 second fade time. Two Button Switch-mount Sensor The two button switch-mount sensor offers control of two presets or zones as determined by the Function and DIP switch settings. Factory Defaults The two button switch-mount sensor ships from the factory in the following default settings:...
  • Page 18 Echoflex Installation Guide Switch-mount Occupancy Sensor Double-tap the button to toggle the preset using a 1/2 second fade time. Note: *DIP switch 1 is set to On by factory default, which reserves Rotary and DIP Switches button control 2 for Off functionality. Reference on page 5 for instructions to change this default setting.
  • Page 19 Echoflex Installation Guide Switch-mount Occupancy Sensor Custom While the two button switch-mount sensor supports the following default button actions in Custom mode, complete customization is available when using ElahoAccess. In Custom mode, using default behaviors, an occupancy event activates the zone that is configured to button 1 at full, and the vacancy detection event deactivates the Zone (set to 0%).
  • Page 20: Sensor Coverage

    Echoflex Installation Guide Switch-mount Occupancy Sensor Sensor Coverage Top View 14 m (45 ft) (30 ft) 180° (30 ft) 14 m (45 ft) Side View 15° 14 m (45 ft) Dual Tech Switch-mount Occupancy Sensor Page 20 of 20 Echoflex Solutions, Inc.

Table of Contents