8588A/8558A
Remote Programmer's Manual
:ROUTe:CURRent:RANGe
<range>|MIN|MAX|DEF
:ROUTe:CURRent:RANGe?
[MIN|MAX|DEF]
:ROUTe:CURRent:THReshold
<numeric>|MIN|MAX|DEF
:ROUTe:SIGNal BNC|ACI|ACV
:ROUTe:SIGNal?
:ROUTe:VOLTage:RANGe
<range>|MIN|MAX|DEF
:ROUTe:VOLTage:RANGe?
[MIN|MAX|DEF]
:ROUTe:VOLTage:THReshold
<numeric>|MIN|MAX|DEF
[:SENSe]:PERiod
:COUPling AC|DC
:COUPling?
:BWLimit[:STATe] <boolean>
:BWLimit[:STATe]?
:GATE <nrf>|MIN|MAX|DEF
:GATE? [MIN|MAX|DEF]
:ROUTe:SIGNal BNC|ACI|ACV
:ROUTe:SIGNal?
:ROUTe:BNC:IMPedance 50R|HIGH
:ROUTe: BNC:IMPedance?
:ROUTe:CURRent:RANGe
<range>|MIN|MAX|DEF
:ROUTe:CURRent:RANGe?
[MIN|MAX|DEF]
:ROUTe:VOLTage:RANGe
<range>|MIN|MAX|DEF
:ROUTe:VOLTage:RANGe?
[MIN|MAX|DEF]
30
Table 6. Command Summary (cont.)
Keyword
Description
Sets the current range to be used if the input path is set to ACI
signal
Returns the current range setting
Set Threshold to the numeric value or to the MIN, MAX, or
Default threshold setting (-200 % to 200 % of Range)
Sets the Frequency|Period input path
Returns the Frequency|Period input path setting
Sets the voltage range to be used if the input path is set to ACV
signal or to the MIN, MAX, or Default setting
Returns the voltage range setting or the MIN, MAX, or Default
value
Set Threshold to the numeric value or to the MIN, MAX, or
Default threshold setting (-200 % to 200 % of Range)
Sets the frequency|Period path to AC or DC coupled
Returns the coupling setting
Sets the bandwidth limit ON or OFF
Returns the Bandwidth limit setting
Set gate time to the numeric value or to the MIN, MAX, or
Default setting
Returns the selected gate setting, or if specified, the MIN, MAX,
or Default gate setting
Sets the Frequency|Period input path
Returns the Frequency|Period input path setting
Sets the impedance for the rear panel BNC input
Returns the impedance set for the rear panel BNC input
Sets the current range to be used if the input path is set to ACI
signal
Returns the current range setting
Sets the voltage range to be used if the input path is set to ACV
signal or to the MIN, MAX, or Default setting
Returns the voltage range setting or the MIN, MAX, or Default
value
Need help?
Do you have a question about the 8588A and is the answer not in the manual?