ZyXEL Communications U-336S User Manual page 90

Zyxel user's manual modem u-336s, u-336sa
Hide thumbs Also See for U-336S:
Table of Contents

Advertisement

Command
+FDT
+FEA=n
+FIE=n
+FIP
+FIS=vr,br,wd,l
n,df,ec,bf,st
+FKS
+FLI="string"
+FLO=n
+FLP=n
76 Fax Operation
Value Description
document reception
Transmit phase C data command: releases
the DCE to proceed with negotiation
Phase C received EOL alignment
parameter
n=0
Determine that T.4 EOL patterns are bit
aligned (as received).
n=1
Determine that the last received bits of T.4
EOL patterns are byte aligned by the
DCE, with necessary zero fill bits inserted.
Procedure interrupt parameter
n=0
Procedure interrupt requests from the
remote station are ignored, and not
reported to the DTE.
n=1
Procedure interrupt requests from the
remote station are accepted, negotiated
and reported using the +FVO response.
Initialize facsimile parameters to factory
default.
Current session parameter. refer to
+FDCC Class 2 command in previous
section parameter settings.
Session termination command.
Local ID string parameter.
Flow control options:
n=0
No flow control.
n=1
Set XON/XOFF software flow control.
n=2
Set CTS/RTS hardware flow control.
Document for polling command:
n=0
The DTE has no document for polling.
n=1
Indicated document available for polling.