RTLF / RKLF tape scale
(continued)
RKLF installation drawing
(cabled readhead shown)
For dimensioned cabled and FPC readhead drawings see
Offset 2.02 ±0.25
End clamp
(Pair A-9523-4015)
(page 13)
Reference mark
Overall length = Measuring length + 70 mm
Scale length = Measuring length + 40 mm
ATOM DX
linear installation guide
page 27
and
page
28.
Set-up LED
50
(Pitch tol. ±1°)
0.36
40 µm version
( Yaw tol. ±1°)
0.36
20 µm version
( Yaw tol. ±0.5°)
0.18
50
Readhead / scale orientation
Forward direction of readhead
relative to scale
Reference mark
Scale datum edge
6
15
30
Scale thickness 0.15 (including adhesive)
Calibration rideheight:
2.5 ±0.08
2.5 ±0.04
Operating rideheight:
2.5 ±0.11
2.5 ±0.055
Dimensions and tolerances in mm
(Roll tol. ±1°)
0.22
13
(40 µm version)
(20 µm version)
(40 µm version)
(20 µm version)