D9412GV2/D7412GV2 | Program Entry Guide | 2.0

Test Reports

To send a single Test Report (
enable Sked Function Code #9 (Test Report) in the
Skeds section of the program. Refer to Table 11.
To expand this Test Report to include any off-normal
point condition or other off-normal conditions of
events listed in Diag Reports as a Non-status Event
following a Test Report,
2.2 Phone Parameters on page 10 must be programmed
Yes. Refer to Table 12 on page 18.
Events R# Log Threshold, R# Log Overflow, and R#
RPS Fail are added to the reports sent with Expanded
Test Reports if
RPS Reports
are enabled.
To initiate a Status Report that includes all R# S: ____
Events as a Status Event, Sked Function Code #10
must be enabled in the Skeds section of the program.
Sending off-normal conditions as a Status Report
following a Test Report is required by some
automation systems. Sending off-normal conditions as
a Non-status Report that follows a Test Report is
required for other automation systems.
An off-normal condition is any point that is missing,
trouble, supervisory, or in alarm. Also, points not
cleared at the keypad report as off-normal.
The control panel can generate an Expanded Off-
Normal Test Report by using Sked Function Code 28
or a Non-Expanded Off-Normal Test Report using
Sked Function Code 29. To generate this event, one or
more points must be in an off-normal state at the time
the Sked executes. Expanded Off-Normal Test Reports
include the Off Normal Test Report Event as well as
events for any points that are in an off-normal state at
the time the report is generated. Non-Expanded Off-
Normal Test Report Events are sent only when a point
is in the off-normal state but sends only the Off-
Normal Test Report Event.
Bosch Security Systems | 5/05 | F001U003636B
R# Test Report
),
Expand Test Rpt
in Section
and
Expand Test Rpt
GV2MAIN

Table 11: Test Reports

Report
Selections
R# S: Alarm
Yes, No
R# S: Trouble
Yes, No
R# S:
Yes, No
Supervised
R# Status
Yes, No
Report
R# S: Open
Yes, No
R# S: Close
Yes, No
R# Test
Yes, No
Report
R# S: Perim
Yes, No
Inst
R# S: Perim
Yes, No
Delay
R# S: Fire
Yes, No
Supv
R# S: Fire
Yes, No
Alarm
R# S: Fire Trbl
Yes, No
R# S: Msng
Yes, No
Fire
R# S:
Yes, No
MsngBurgTr
R# S:
Yes, No
MsngBurgAl
R# S:
Yes, No
FireSpMsng
R# S:
Yes, No
SuperMsng
R# S:
Yes, No
DrLeftOpen

Diag Reports

Selecting Yes enables sending a report when the event
occurs. If the off-normal state of the following events
(indicated with an *) still exist, they report when a Test
Test Reports
Report (refer to the
Section 2.3.8 Dialing Attempts on page 14) is enabled and
Expanded Test Rpt is programmed Yes.
EN | 17
Report Description
Status Alarm
Status Trouble
Status Supervised
Status
Status Open
Status Close
Test
Status Perimeter
Instant Arm
Status Perimeter
Delay Arm
Status Fire
Supervision
Status Fire Alarm
Report
Status Fire Trouble
Status Fire Missing
Status Burg Missing
Trouble
Status Burg Missing
Alarm
Status Fire
Supervision Missing
Status Non-fire
Supervision Missing
Status Door Left
Open
sub-prompt in