Routing Destination Communication
Failures
When the

R# Primary Device

the central station after one or two attempts (refer to
RG# 1 Attempt
in Route Group Attempts on page 131),
it then attempts to connect with the
Device
(phone number or SDI Path). The central
station receives the original event with a COMM FAIL
PHONE# = (1, 2, 3, or 4) event modifier, if the
Primary Device
destination is a phone number.
R# Primary Device
If the
station receives the original event with a COMM FAIL
RG# SDI## (SDI Path 1 = 88, SDI Path 2 = 89, SDI
Path 3 = 90, SDI Path 4 = 91) event modifier. When
all attempts to both the
Backup Device
fail, a Comm Fail RG# Event is
generated. Comm Restore Events are not generated.
2.3.7
Message Prioritization within a Route
Number
The D9412GV2/D7412GV2 Control Panels meet the
digital reporting requirements for UL 864. Fire Alarm
Events have the highest priority and reports are sent
first for each group. Other events are sent in the
following order: Panic, Duress, Medical, Intrusion
Alarm, Supervisory, and all troubles and restorals.
To comply with NFPA and UL864, you
must program Route 1 to send a report of
only Fire Alarm Events to ensure the fastest
reporting time.
2.3.8

Dialing Attempts

The D9412GV2 and D7412GV2 Control Panels have
an
RG# 1 Attempt
prompt (refer to Route Group
Attempts on page 131).
RG# 1 Attempt
If
is set to No, the control panel
makes up to six dialing attempts using the primary
device within a route group. If unsuccessful, it makes
up to four dialing attempts using the backup device
before initiating a Comm Fail Report. When only one
destination is programmed, the control panel makes
ten attempts to contact that destination. Each group
takes approximately 10 minutes to go into Comm Fail.
RG# 1 Attempt
If
is set to Yes, the control panel
makes only one attempt to contact the primary device
before attempting to contact the backup device. The
route group still makes a total of ten attempts;
R# Primary Device
however, the
and then the
R# Backup Device
Bosch Security Systems | 5/05 | F001U003636B
fails to connect with
R# Backup
R#
is an SDI Path, the central
R# Primary Device
and
makes five attempts
makes five attempts.
GV2MAIN

Route #

Default:
Selection:
1
2
3
4
Enter the number specifying the route group to
program. The route represents the group you wish to
send a group of reports. Group 1 is the first group to
send a report and Group 4 is the last group to send a
R#
report. Each group has a primary and a backup device.
The primary device is the first (most important)
destination used to reach the programmed route within
this group. The backup device is used if the primary
device fails.
R# Primary Device
Default:
Selection:
1
2
3
4
Enter the number specifying the primary device.
1
1 to 4
First group sent
Second group sent
Third group sent
Fourth group sent
Blank
Blank, 1 to 4
Phone 1 or SDI Path 1 is this group's
primary destination.
Phone 2 or SDI Path 2 is this group's
primary destination.
Phone 3 or SDI Path 3 is this group's
primary destination.
Phone 4 or SDI Path 4 is this group's
primary destination.
EN | 14