D9412GV2/D7412GV2 | Program Entry Guide | 6.0
Enable Ext Modem
Default:
No
Selection:
Yes or No
Yes
Enable SDI Address 88 for use with
an external modem.
No
Disable SDI Address 88 for use with
an external modem.
Setting this item to Yes instructs the control panel that
SDI Address 88 is enabled for use with an external
modem. For further information on Local RPS
programming, refer to the RPS Operations Manual
(P/N: 38849).
Setting this item to Yes disables Enhanced
Communication and SDI RPS for use over
a LAN or WAN.
Answer Armed
Default:
7
Selection:
0 to 15
0
No answer when all areas are Master
Armed.
0 to 15
The control panel answers the phone
after the specified number of rings
when all areas are Master Armed.
Determines the number of rings after which the
external modem automatically answers a call if all
areas are Master Armed.
Answer Disarmed
Default:
7
Selection:
0 to 15
0
No answer when any area is
Perimeter Armed or Disarmed.
0 to 15
The control panel answers the phone
after the specified number of rings
when any area is Perimeter Armed or
Disarmed.
Determines the number of rings after which the
external modem automatically answers a call if any
area is Perimeter Armed or Disarmed.
Bosch Security Systems | 5/05 | F001U003636B
GV2AUX
RPS Line Monitor
Default:
No
Selection:
Yes or No
Not used. Keep this item set to No.
Seize Relay
Default:
No
Selection:
Yes or No
Not used. Keep this item set to No.
Modem Init String
Default:
ATE0
Selection:
A to Z (capital letters only), 0 to 9,
[SPACE], ! " # $ % & ' ( ) * + , - . / : ;
< = > ? @ [ \ ] ^ _
Determines which initialization string the control panel
sends to the external modem when the control panel
powers up.
If special characters are required, Modem
Init String can be programmed
successfully only from RPS. The D5200
Programmer allows only the characters
shown in the Modem Init String default
selections.
RPS Dial String
Default:
ATDT
Selection:
Not available
Not used.
EN | 126