P## Local While Armed; P## Disable Rst; P## Fa Retrnable; P## Bp Retrnable - Bosch D9412GV2 Program Entry Manual

Table of Contents

Advertisement

D9412GV2/D7412GV2 | Program Entry Guide | 4.0

P## Local While Armed

Default:
No
Selection:
Yes or No
Yes
Suppress Alarm, Trouble and
Restoral* Reports from this point
while the area to which it is assigned is
armed.
No
Report events occurring from this
point while the area is armed.
*
Transmission of Restoral Reports continues if the alarm,
trouble, or bypass (by Sked, RPS, or Swinger bypass)
condition occurred when the area disarmed, and the point
restored.
Allows a controlled point (P## Type 1, 2, 3), to report
Alarms, Troubles, and Restoral Reports only when the
area is disarmed. This prompt does not affect local
annunciation.
Local While Armed suppresses all reports
from 24-hour points. Do not use P## Type
0 for this prompt. This setting works only for
disarmed points. Type 0 is a 24-hour,
always armed point. Choose any Type other
than 0, and use a point response that
reports an alarm whether or not the point is
armed. For instance, P## Type 1 and P##
Response 9 reports an alarm on a trouble
or a short whether or not the area is
disarmed.
Local While Armed affects Keyswitch
Points. This prompt suppresses keyswitch
(alarms, troubles, and restorals) and D279
(opening, closing, troubles, and restorals).
Do not use this parameter for controlled
points that arm or disarm.

P## Disable Rst

Default:
No
Selection:
Yes or No
Yes
Enable Restoral Reports from this
point.
No
Disable Restoral Reports from this
point.
* Transmission of Restoral Reports continues if the alarm,
trouble, or bypass (by Sked, RPS, or Swinger bypass)
condition occurred when the area disarmed, and the point
restored.
Use this option to disable any Restoral Reports from
this point after it returns to normal from an alarm or
trouble condition.
Bosch Security Systems | 5/05 | F001U003636B
RADXPNTS

P## FA Retrnable

Default:
No
Selection:
Yes or No
Yes
This point automatically returns to the
system when it restores to normal.
No
This point stays out of the system until
the area is disarmed.
Use this option to allow points that were force armed
out of the area to return back to the armed state when
they become normal again without having to disarm
the system.
Use on loading dock doors, that must
remain open until loading is completed.
After the loading dock door is closed, the
point detects any subsequent opening and
reports an alarm.

P## BP Retrnable

Default:
No
Selection:
Yes or No
Yes
This point automatically returns to
the system when the area is disarmed.
No
This point stays out of the system
through arming and disarming cycles.
Use this option to return a point that was bypassed,
force armed, or swinger bypassed back into the system
when the area to which this point is assigned is
disarmed
Set this item to No for Interlock points.
When the point cannot return to the system
through disarming, the point must be
manually unbypassed using the Unbypass?,
keypad function, Sked Functions 4 and 5,
or remote programming software (RPS).
For Force Armed points to remain
bypassed, ensure that P## FA Retrnable
is set to No.
EN | 91