OPERATION OF THE OPERATOR

6.7.1 Operator system parameters (OS)

Only the meanings of the parameter values are described in the following. Value range, data
length and data type; Access mode and the default values can be taken from COMBIVIS.
OS00
Operator type
Value
Meaning
e.g. 12700
Display of the operator type (configuration number)
12710 : F6 Ethernet
12700 : F6 default + USB
OS01
Password
Value
Meaning
-1...-9
Displays the actual password level of the operator, independent of the drive converter.
Is used to enter the operator password level and is also the actual file level:
550 = user read-only, file level = 5
660 = user read/write, file level = 6
Supervisor, file level = 7
OS02
FTP mode
Value
Meaning
0...1
Activation of the FTP mode. The FTP mode can also be started via the main menu.
0: Inactive
1: Active
OS03
Startup mode
Value
Meaning
0...8
The startup mode determines the display during switch on.
0: Main menu
1: Inverter parameter
2: Operator Parameter
3: Parameter saving
4: Download mode
5: Worklist mode
6: File operations
7: FTP mode
8: Test mode
26
Parameter address
0x0180
0x2181
Parameter address
0x2386
Parameter address
Parameter address
0x2387