Operator - KEB COMBIVERT F5 Series Instruction Manual

Control circuit from v3.2
Hide thumbs Also See for COMBIVERT F5 Series:
Table of Contents

Advertisement

Installation and Connection
2.3

Operator

As an accessory to the local or external (option: cable 00.F5.0C0-1xxx) operation an operator is necessary. To
prevent malfunctions, the inverter must be brought into nOP status before connecting / disconnecting the operator
(open control release terminal). When starting the inverter, it is started with the last stored values or factory
setting.
X6C
RS 232 cable
Part number
0058025-001D
Length 3 m
GB - 10
Digital operator (part number 00.F5.060-1000)
Interface operator (part number 00.F5.060-2000)
x x 5-digit LED Display
x x Operating-/Error display
Normal "LED on"
Error "LED blinks"
-
x Interface control
Transmit "LED on"
x x Double function keyboard
-
x X6B HSP5 programming and diagnostic
interface
-
x X6C RS232/RS485
Only use the operator interface for the serial data transfer to RS232/485. The direct
connection, PC to the inverter is only valid with a cable (part number 00.F5.0C0-0010),
otherwise, it would lead to the destruction of the PC-interface !
PIN RS485
Signal
1
-
-
2
-
TxD
3
-
RxD
4
A'
RxD-A
5
B'
RxD-B
6
-
VP
7
C/C'
DGND
8
A
TxD-A
9
B
TxD-B
9-pole Sub-D socket
PC
Housing (PE)
Meaning
reserved
transmission signal RS232
receive signal RS232
receive signal A RS485
receive signal B RS485
Voltage supply +5 V (Imax=50 mA)
Data reference potential
transmission signal A RS485
transmission signal B RS485
2
3
5
START
ENTER
FUNC.
F/R
SPEED
STOP
X6B
C O M B I V E R T
X6C
9-pole SUB-D connector
2
Operator
3
7
X6D

Hide quick links:

Advertisement

Table of Contents
loading