5

Error Indication

5
Error Indication
SST-PN-2-PE board is provided with LEDs for circuit board status
indication. These LEDs indicate the following conditions.
1. SYS LED
2. NET LED
3. IRT LED (reserved)
4. SYNC LED (reserved)
SYS
NET
Off
Off
Green
Off
Green
Red blinking Default PROFINET configuration.
Green
Green
blinking
Green
Green
Red
Green
Red
Red
5-1
Comments
Card not running.
PROFINET protocol stack is stopped.
Card configured, but not connected to PROFINET
devices/controller.
Card configured, connected to PROFINET
devices/controller.
Card is booting.
Initialization internal error.
• Turn OFF and ON the YRC1000micro main power
to start the system again.
• Check the connection of the SST-PN-2-PE board
and the YRC1000micro PCI Express slot.
• Replace the SST-PN-2-PE board.
HW1485152
HW1485152