GRAPHTEC FC8600-60 Service Manual page 89

Cutting plotter
Hide thumbs Also See for FC8600-60:
Table of Contents

Advertisement

(8) Adjust the gap to a value in the range of 0 mm to 0.2 mm.
Press the UP or DOWN ARROW key to adjust the gap.
Cross cutter dog
(9) Press the left arrow key to display the menu shown below.
(10) Press the F4 key to confirm the gap.
If the cross cutter dog presses on the cutter release plate too much, a position alarm error will be
displayed.
At this time reduce the C-CUTTER POS ADJ value.
(11) Press the ENTER key to store the setting.
(12) Turn off the power to exit from the adjustment menu.
FC8600-UM-251-9370
Cross cutter release plate
0 to 0.2 mm
7-29