Item No. Description
1
Back plate
2
Door Closer (1601LAP or 1601BFLAP)
3
Motor Assembly (5700M)
4
Inverter (5700IN)
5
Cover (5700COV)
6
On/Off switch
7
Circuit Breaker
Tools required:
• 1/8" allen wrench (included)
• Flat blade screwdriver (potentiometer & terminal size)
• Screwdriver (Phillips size 2)
• Tape ruler
! If local code requires unit to be hard wired instead of using the
plug-in type power supply cord supplied with this version of the
unit, the unit MUST be returned to the manufacturer and
replaced with a unit designed to be hard wired.
! To reduce the risk of shock, this operator has a grounding type
plug, that has a third (grounding) pin. This plug will only fit into a
grounding type outlet. If the plug does not fit into the outlet,
contact a qualified electrician to install the proper outlet. Do not
change the plug in any way.
1
3
10
12
!
with Optional Plug-in Power Input
Installation and Instruction Manual
4
11
Item No. Description
8
120VAC Power Input (C14 Appliance)
9
Activation Inputs
10
Door Open/Closed Position Magnets
11
Optional RF Receiver
12
Power Supply - 1.1A 24V
13
18 inch max. Power Cord (not shown)
• Power drill and set of drill bits
• Center punch
• Wire stripper
• #7 drill 1/4-20 tap (metal frame install)
WARNINGS
! Always disconnect the main power to the operator prior to
servicing or cleaning.
! This operator is for indoor use only.
! To reduce the risk of injury or person, use the operator only with
Pedestrian Swing doors.
! 120VAC power supplied to the operator must be a dedicated
circuit from the main circuit breaker panel and must NOT be
connected into any building lighting system that operates
flourescent lights.
! Maximum door size: 48 in (1219mm) wide x 250 lb (113.4kg).