Homing Using External Zero Mark - Siemens SIMOTION ADI4 Manual

Analog drive interface for 4 axes
Hide thumbs Also See for SIMOTION ADI4:
Table of Contents

Advertisement

Parameter assignment
3.5 Function parameters
3.5.9

Homing using external zero mark

System structure
Figure 3-6
Function
Once the controller requests homing, the ADI4 transmits the actual encoder value to the
controller as the home position the next time it detects an external zero mark signal.
Without 611U conformant mode
The controller must define the relevant function via encoder control word G1_STW:
● Function 2 (Homing via rising edge of external zero mark)
● Function 3 (Homing via falling edge of external zero mark)
With 611U conformant mode
The relevant signal for the axis to be homed (e.g. Axis 1) must be set in the digital output
word:
● Digital output word:
Note
Homing using an external zero mark requires 611U conformant mode to be selected.
52
Basic system structure: Homing using external zero mark
Bit 0: = 1 ⇒ "Axis 1: Rising edge of external zero mark 1 (X6-2, Pin 2)"
SIMOTION ADI4 - Analog Drive Interface for 4 Axes
Manual, 05/2009, 6FC5 297-0BA01-0BP6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents